Abstract

The external controller (EC) of a series flexible AC transmission system (FACTS) device, which is the series capacitive reactance compensator (SCRC), can provide effective damping of low-frequency oscillations in a power system. The saturation limiter in the EC is used to enforce practical limits resulting from system restrictions such as equipment and component ratings. In this paper, the effect of a saturation limiter on the overall system dynamic behavior is analyzed. Also, a systematic nonlinear tuning method is proposed to determine the optimal values for saturation limits based on the sensitivity trajectory analysis.

Original languageEnglish
Title of host publicationProceedings - IEEE INDIN 2008
Subtitle of host publication6th IEEE International Conference on Industrial Informatics
Pages1626-1631
Number of pages6
DOIs
Publication statusPublished - 2008 Oct 31
EventIEEE INDIN 2008: 6th IEEE International Conference on Industrial Informatics - Daejeon, Korea, Republic of
Duration: 2008 Jul 132008 Jul 16

Other

OtherIEEE INDIN 2008: 6th IEEE International Conference on Industrial Informatics
CountryKorea, Republic of
CityDaejeon
Period08/7/1308/7/16

Fingerprint

Limiters
Tuning
Controllers
Dynamical systems
Damping
Trajectories
Flexible AC transmission systems

All Science Journal Classification (ASJC) codes

  • Computer Science Applications
  • Information Systems

Cite this

Baek, S. M., & Park, J. W. (2008). Optimal tuning for saturation limiter of a series FACTS device. In Proceedings - IEEE INDIN 2008: 6th IEEE International Conference on Industrial Informatics (pp. 1626-1631). [4618364] https://doi.org/10.1109/INDIN.2008.4618364
Baek, Seung Mook ; Park, Jung Wook. / Optimal tuning for saturation limiter of a series FACTS device. Proceedings - IEEE INDIN 2008: 6th IEEE International Conference on Industrial Informatics. 2008. pp. 1626-1631
@inproceedings{e09f9b6dc84141a5900f236f2eac5d8a,
title = "Optimal tuning for saturation limiter of a series FACTS device",
abstract = "The external controller (EC) of a series flexible AC transmission system (FACTS) device, which is the series capacitive reactance compensator (SCRC), can provide effective damping of low-frequency oscillations in a power system. The saturation limiter in the EC is used to enforce practical limits resulting from system restrictions such as equipment and component ratings. In this paper, the effect of a saturation limiter on the overall system dynamic behavior is analyzed. Also, a systematic nonlinear tuning method is proposed to determine the optimal values for saturation limits based on the sensitivity trajectory analysis.",
author = "Baek, {Seung Mook} and Park, {Jung Wook}",
year = "2008",
month = "10",
day = "31",
doi = "10.1109/INDIN.2008.4618364",
language = "English",
isbn = "9781424421718",
pages = "1626--1631",
booktitle = "Proceedings - IEEE INDIN 2008",

}

Baek, SM & Park, JW 2008, Optimal tuning for saturation limiter of a series FACTS device. in Proceedings - IEEE INDIN 2008: 6th IEEE International Conference on Industrial Informatics., 4618364, pp. 1626-1631, IEEE INDIN 2008: 6th IEEE International Conference on Industrial Informatics, Daejeon, Korea, Republic of, 08/7/13. https://doi.org/10.1109/INDIN.2008.4618364

Optimal tuning for saturation limiter of a series FACTS device. / Baek, Seung Mook; Park, Jung Wook.

Proceedings - IEEE INDIN 2008: 6th IEEE International Conference on Industrial Informatics. 2008. p. 1626-1631 4618364.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Optimal tuning for saturation limiter of a series FACTS device

AU - Baek, Seung Mook

AU - Park, Jung Wook

PY - 2008/10/31

Y1 - 2008/10/31

N2 - The external controller (EC) of a series flexible AC transmission system (FACTS) device, which is the series capacitive reactance compensator (SCRC), can provide effective damping of low-frequency oscillations in a power system. The saturation limiter in the EC is used to enforce practical limits resulting from system restrictions such as equipment and component ratings. In this paper, the effect of a saturation limiter on the overall system dynamic behavior is analyzed. Also, a systematic nonlinear tuning method is proposed to determine the optimal values for saturation limits based on the sensitivity trajectory analysis.

AB - The external controller (EC) of a series flexible AC transmission system (FACTS) device, which is the series capacitive reactance compensator (SCRC), can provide effective damping of low-frequency oscillations in a power system. The saturation limiter in the EC is used to enforce practical limits resulting from system restrictions such as equipment and component ratings. In this paper, the effect of a saturation limiter on the overall system dynamic behavior is analyzed. Also, a systematic nonlinear tuning method is proposed to determine the optimal values for saturation limits based on the sensitivity trajectory analysis.

UR - http://www.scopus.com/inward/record.url?scp=54849423249&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=54849423249&partnerID=8YFLogxK

U2 - 10.1109/INDIN.2008.4618364

DO - 10.1109/INDIN.2008.4618364

M3 - Conference contribution

SN - 9781424421718

SP - 1626

EP - 1631

BT - Proceedings - IEEE INDIN 2008

ER -

Baek SM, Park JW. Optimal tuning for saturation limiter of a series FACTS device. In Proceedings - IEEE INDIN 2008: 6th IEEE International Conference on Industrial Informatics. 2008. p. 1626-1631. 4618364 https://doi.org/10.1109/INDIN.2008.4618364