TY - JOUR
T1 - Optimum design of an A-pillar trim with rib structures for occupant head protection
AU - Kim, Hyoung Gon
AU - Kang, Shinill
N1 - Copyright:
Copyright 2004 Elsevier Science B.V., Amsterdam. All rights reserved.
PY - 2000
Y1 - 2000
N2 - NHTSA (National Highway Traffic Safety Administration) has been conducting biomechanical studies to reduce head injuries sustained during automotive collision. Furthermore, NHTSA added the new regulation to the FMVSS201 (Federal Motor Vehicle Safety Standard), limiting the equivalent HIC(Head Injury Criterion) value under 1000. In the present study, a methodology is developed for the optimum design of the A-pillar trim with rib structures, which can maximize the energy dissipation during the head impact. The design variables for the rib structures are the transverse spacing, the longitudinal spacing, and the thickness. The required set of design variables is decided on the bases of the design of experiments. A series of simulations for head impact to A-pillar trim are carried out by using the LS-DYNA3D, and the HIC(d) values are computed using results from simulations, which utilize design variables determined by a combination of the central composite design and the full factorial design. A proper regression function with R-square value above 0.9 was constructed using the response surface method, and it was used as an objective function for optimization. A HIC(d) value under 850 for 15mph head-trim impact was obtained using the rib structures suggested by the present design methodology.
AB - NHTSA (National Highway Traffic Safety Administration) has been conducting biomechanical studies to reduce head injuries sustained during automotive collision. Furthermore, NHTSA added the new regulation to the FMVSS201 (Federal Motor Vehicle Safety Standard), limiting the equivalent HIC(Head Injury Criterion) value under 1000. In the present study, a methodology is developed for the optimum design of the A-pillar trim with rib structures, which can maximize the energy dissipation during the head impact. The design variables for the rib structures are the transverse spacing, the longitudinal spacing, and the thickness. The required set of design variables is decided on the bases of the design of experiments. A series of simulations for head impact to A-pillar trim are carried out by using the LS-DYNA3D, and the HIC(d) values are computed using results from simulations, which utilize design variables determined by a combination of the central composite design and the full factorial design. A proper regression function with R-square value above 0.9 was constructed using the response surface method, and it was used as an objective function for optimization. A HIC(d) value under 850 for 15mph head-trim impact was obtained using the rib structures suggested by the present design methodology.
UR - http://www.scopus.com/inward/record.url?scp=0040185963&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0040185963&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:0040185963
VL - 106
SP - 93
EP - 100
JO - American Society of Mechanical Engineers, Design Engineering Division (Publication) DE
JF - American Society of Mechanical Engineers, Design Engineering Division (Publication) DE
SN - 1521-4613
ER -