Parameter optimization of SFCL with wind-turbine generation system based on its protective coordination

Woo Jae Park, Byung Chul Sung, Kyung Bin Song, Jung Wook Park

Research output: Contribution to journalArticle

26 Citations (Scopus)

Abstract

This paper describes a study to determine the optimal resistance of a superconducting fault current limiter (SFCL) connected to a wind-turbine generation system (WTGS) in series considering its protective coordination. The connection of the WTGS to the electric power grid may have serious effects on the stability and reliability of the overall system during a contingency due to the increase in fault currents. Moreover, it causes malfunction in the protective devices such as overcurrent relays (OCRs). To deal with this problem, the SFCL is applied to reduce the level of fault current increased by the connection of the WTGS. Then, to determine the optimal parameter of the SFCL, protective coordination between the existing multiple OCRs is considered based on the computation of fault current by the equivalent voltage source method. The effectiveness of the optimal resistance for the SFCL is evaluated by the time-domain simulation with the power systems computer aided design/electromagnetic transients including DC (PSCAD/EMTDC) software. The results show that protective coordination is well maintained without changing the previous settings of existing OCRs by applying the SFCL with its optimal parameter. Therefore, the system can keep its suitable reliability even when the level of fault current is increased by connecting the WTGS to the power system.

Original languageEnglish
Article number5645714
Pages (from-to)2153-2156
Number of pages4
JournalIEEE Transactions on Applied Superconductivity
Volume21
Issue number3 PART 2
DOIs
Publication statusPublished - 2011 Jun 1

Fingerprint

Superconducting fault current limiters
wind turbines
Electric fault currents
Wind turbines
optimization
relay
Computer aided design
contingency
malfunctions
computer aided design
electric power
Electric potential
direct current
grids
electromagnetism
computer programs

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Electrical and Electronic Engineering

Cite this

@article{8b8479c22c4b4bcc96ebf2e7c515a565,
title = "Parameter optimization of SFCL with wind-turbine generation system based on its protective coordination",
abstract = "This paper describes a study to determine the optimal resistance of a superconducting fault current limiter (SFCL) connected to a wind-turbine generation system (WTGS) in series considering its protective coordination. The connection of the WTGS to the electric power grid may have serious effects on the stability and reliability of the overall system during a contingency due to the increase in fault currents. Moreover, it causes malfunction in the protective devices such as overcurrent relays (OCRs). To deal with this problem, the SFCL is applied to reduce the level of fault current increased by the connection of the WTGS. Then, to determine the optimal parameter of the SFCL, protective coordination between the existing multiple OCRs is considered based on the computation of fault current by the equivalent voltage source method. The effectiveness of the optimal resistance for the SFCL is evaluated by the time-domain simulation with the power systems computer aided design/electromagnetic transients including DC (PSCAD/EMTDC) software. The results show that protective coordination is well maintained without changing the previous settings of existing OCRs by applying the SFCL with its optimal parameter. Therefore, the system can keep its suitable reliability even when the level of fault current is increased by connecting the WTGS to the power system.",
author = "Park, {Woo Jae} and Sung, {Byung Chul} and Song, {Kyung Bin} and Park, {Jung Wook}",
year = "2011",
month = "6",
day = "1",
doi = "10.1109/TASC.2010.2090855",
language = "English",
volume = "21",
pages = "2153--2156",
journal = "IEEE Transactions on Applied Superconductivity",
issn = "1051-8223",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "3 PART 2",

}

Parameter optimization of SFCL with wind-turbine generation system based on its protective coordination. / Park, Woo Jae; Sung, Byung Chul; Song, Kyung Bin; Park, Jung Wook.

In: IEEE Transactions on Applied Superconductivity, Vol. 21, No. 3 PART 2, 5645714, 01.06.2011, p. 2153-2156.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Parameter optimization of SFCL with wind-turbine generation system based on its protective coordination

AU - Park, Woo Jae

AU - Sung, Byung Chul

AU - Song, Kyung Bin

AU - Park, Jung Wook

PY - 2011/6/1

Y1 - 2011/6/1

N2 - This paper describes a study to determine the optimal resistance of a superconducting fault current limiter (SFCL) connected to a wind-turbine generation system (WTGS) in series considering its protective coordination. The connection of the WTGS to the electric power grid may have serious effects on the stability and reliability of the overall system during a contingency due to the increase in fault currents. Moreover, it causes malfunction in the protective devices such as overcurrent relays (OCRs). To deal with this problem, the SFCL is applied to reduce the level of fault current increased by the connection of the WTGS. Then, to determine the optimal parameter of the SFCL, protective coordination between the existing multiple OCRs is considered based on the computation of fault current by the equivalent voltage source method. The effectiveness of the optimal resistance for the SFCL is evaluated by the time-domain simulation with the power systems computer aided design/electromagnetic transients including DC (PSCAD/EMTDC) software. The results show that protective coordination is well maintained without changing the previous settings of existing OCRs by applying the SFCL with its optimal parameter. Therefore, the system can keep its suitable reliability even when the level of fault current is increased by connecting the WTGS to the power system.

AB - This paper describes a study to determine the optimal resistance of a superconducting fault current limiter (SFCL) connected to a wind-turbine generation system (WTGS) in series considering its protective coordination. The connection of the WTGS to the electric power grid may have serious effects on the stability and reliability of the overall system during a contingency due to the increase in fault currents. Moreover, it causes malfunction in the protective devices such as overcurrent relays (OCRs). To deal with this problem, the SFCL is applied to reduce the level of fault current increased by the connection of the WTGS. Then, to determine the optimal parameter of the SFCL, protective coordination between the existing multiple OCRs is considered based on the computation of fault current by the equivalent voltage source method. The effectiveness of the optimal resistance for the SFCL is evaluated by the time-domain simulation with the power systems computer aided design/electromagnetic transients including DC (PSCAD/EMTDC) software. The results show that protective coordination is well maintained without changing the previous settings of existing OCRs by applying the SFCL with its optimal parameter. Therefore, the system can keep its suitable reliability even when the level of fault current is increased by connecting the WTGS to the power system.

UR - http://www.scopus.com/inward/record.url?scp=79957922203&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79957922203&partnerID=8YFLogxK

U2 - 10.1109/TASC.2010.2090855

DO - 10.1109/TASC.2010.2090855

M3 - Article

AN - SCOPUS:79957922203

VL - 21

SP - 2153

EP - 2156

JO - IEEE Transactions on Applied Superconductivity

JF - IEEE Transactions on Applied Superconductivity

SN - 1051-8223

IS - 3 PART 2

M1 - 5645714

ER -