Performance of the CMS muon detector and muon reconstruction with proton-proton collisions at s=13 TeV

The CMS Collaboration

Research output: Contribution to journalArticle

60 Citations (Scopus)

Abstract

The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013-2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energy s=13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously. We dedicate this paper to the memory of Prof. Alberto Benvenuti, whose work was fundamental for the CMS muon detector.

Original languageEnglish
Article numberP06015
JournalJournal of Instrumentation
Volume13
Issue number6
DOIs
Publication statusPublished - 2018 Jun 19

Fingerprint

muons
Protons
Collision
Detector
Detectors
collisions
protons
detectors
Luminance
Barycentre
Energy
Specifications
Data storage equipment
Trigger
Spatial Resolution
Instantaneous
Timing
Preparation
Specification
center of mass

All Science Journal Classification (ASJC) codes

  • Mathematical Physics
  • Instrumentation

Cite this

@article{5fc91cb07705416b8b890c18f4a8f8bf,
title = "Performance of the CMS muon detector and muon reconstruction with proton-proton collisions at s=13 TeV",
abstract = "The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013-2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energy s=13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously. We dedicate this paper to the memory of Prof. Alberto Benvenuti, whose work was fundamental for the CMS muon detector.",
author = "{The CMS Collaboration} and Sirunyan, {A. M.} and A. Tumasyan and W. Adam and F. Ambrogi and E. Asilar and T. Bergauer and J. Brandstetter and E. Brondolin and M. Dragicevic and J. Er{\"o} and {Escalante Del Valle}, A. and M. Flechl and M. Friedl and R. Fr{\"u}hwirth and Ghete, {V. M.} and J. Grossmann and J. Hrubec and M. Jeitler and A. K{\"o}nig and N. Krammer and I. Kr{\"a}tschmer and D. Liko and T. Madlener and I. Mikulec and E. Pree and N. Rad and H. Rohringer and J. Schieck and R. Sch{\"o}fbeck and M. Spanring and D. Spitzbart and A. Taurok and W. Waltenberger and J. Wittmann and Wulz, {C. E.} and M. Zarucki and V. Chekhovsky and V. Mossolov and {Suarez Gonzalez}, J. and {De Wolf}, {E. A.} and {Di Croce}, D. and X. Janssen and J. Lauwers and {Van De Klundert}, M. and {Van Haevermaet}, H. and {Van Mechelen}, P. and {Van Remortel}, N. and {Abu Zeid}, S. and F. Blekman and J. D’hondt",
year = "2018",
month = "6",
day = "19",
doi = "10.1088/1748-0221/13/06/P06015",
language = "English",
volume = "13",
journal = "Journal of Instrumentation",
issn = "1748-0221",
publisher = "IOP Publishing Ltd.",
number = "6",

}

Performance of the CMS muon detector and muon reconstruction with proton-proton collisions at s=13 TeV. / The CMS Collaboration.

In: Journal of Instrumentation, Vol. 13, No. 6, P06015, 19.06.2018.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Performance of the CMS muon detector and muon reconstruction with proton-proton collisions at s=13 TeV

AU - The CMS Collaboration

AU - Sirunyan, A. M.

AU - Tumasyan, A.

AU - Adam, W.

AU - Ambrogi, F.

AU - Asilar, E.

AU - Bergauer, T.

AU - Brandstetter, J.

AU - Brondolin, E.

AU - Dragicevic, M.

AU - Erö, J.

AU - Escalante Del Valle, A.

AU - Flechl, M.

AU - Friedl, M.

AU - Frühwirth, R.

AU - Ghete, V. M.

AU - Grossmann, J.

AU - Hrubec, J.

AU - Jeitler, M.

AU - König, A.

AU - Krammer, N.

AU - Krätschmer, I.

AU - Liko, D.

AU - Madlener, T.

AU - Mikulec, I.

AU - Pree, E.

AU - Rad, N.

AU - Rohringer, H.

AU - Schieck, J.

AU - Schöfbeck, R.

AU - Spanring, M.

AU - Spitzbart, D.

AU - Taurok, A.

AU - Waltenberger, W.

AU - Wittmann, J.

AU - Wulz, C. E.

AU - Zarucki, M.

AU - Chekhovsky, V.

AU - Mossolov, V.

AU - Suarez Gonzalez, J.

AU - De Wolf, E. A.

AU - Di Croce, D.

AU - Janssen, X.

AU - Lauwers, J.

AU - Van De Klundert, M.

AU - Van Haevermaet, H.

AU - Van Mechelen, P.

AU - Van Remortel, N.

AU - Abu Zeid, S.

AU - Blekman, F.

AU - D’hondt, J.

PY - 2018/6/19

Y1 - 2018/6/19

N2 - The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013-2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energy s=13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously. We dedicate this paper to the memory of Prof. Alberto Benvenuti, whose work was fundamental for the CMS muon detector.

AB - The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013-2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energy s=13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously. We dedicate this paper to the memory of Prof. Alberto Benvenuti, whose work was fundamental for the CMS muon detector.

UR - http://www.scopus.com/inward/record.url?scp=85049260454&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85049260454&partnerID=8YFLogxK

U2 - 10.1088/1748-0221/13/06/P06015

DO - 10.1088/1748-0221/13/06/P06015

M3 - Article

AN - SCOPUS:85049260454

VL - 13

JO - Journal of Instrumentation

JF - Journal of Instrumentation

SN - 1748-0221

IS - 6

M1 - P06015

ER -