K. Abe, K. Hasegawa, F. Suekane, H. Yuta, S. Dasu, S. Dolinsky, W. Dunwoodie, G. Hallewell, J. Hoeflich, H. Kawahara, Youngjoon Kwon, D. W.G.S. Leith, D. M. Marshall, D. Muller, T. Nagamine, G. Oxoby, T. J. Pavel, B. Ratcliff, P. Rensing, D. Schultz & 7 others S. Shapiro, C. Simopoulos, E. Solodov, P. Stiles, N. Toge, J. Va'vra, S. H. Williams

Research output: Contribution to journalArticle

Abstract

The front end electronics and data acquisition system for the SLD barrel Cherenkov Ring Imaging Detector (CRID) are described. This electronics must provide a 1 % charge division measurement with a maximum acceptable noise level of 2000 electrons (rms). Noise and system performance results are presented for the initial SLD engineering run data.

Original languageEnglish
Pages (from-to)897-900
Number of pages4
JournalIEEE Transactions on Nuclear Science
Volume39
Issue number4
DOIs
Publication statusPublished - 1992 Jan 1

Fingerprint

data acquisition
Data acquisition
acquisition
Electronic equipment
Detectors
Imaging techniques
rings
detectors
electronics
division
engineering
Electrons
electrons

All Science Journal Classification (ASJC) codes

  • Nuclear and High Energy Physics
  • Nuclear Energy and Engineering
  • Electrical and Electronic Engineering

Cite this

Abe, K. ; Hasegawa, K. ; Suekane, F. ; Yuta, H. ; Dasu, S. ; Dolinsky, S. ; Dunwoodie, W. ; Hallewell, G. ; Hoeflich, J. ; Kawahara, H. ; Kwon, Youngjoon ; Leith, D. W.G.S. ; Marshall, D. M. ; Muller, D. ; Nagamine, T. ; Oxoby, G. ; Pavel, T. J. ; Ratcliff, B. ; Rensing, P. ; Schultz, D. ; Shapiro, S. ; Simopoulos, C. ; Solodov, E. ; Stiles, P. ; Toge, N. ; Va'vra, J. ; Williams, S. H. / Performance of the Front End Electronics and Data Acquisition System for the Sld Cherenkov Ring Imaging Detector. In: IEEE Transactions on Nuclear Science. 1992 ; Vol. 39, No. 4. pp. 897-900.
@article{18136c0de86c48f8942bcd9044602385,
title = "Performance of the Front End Electronics and Data Acquisition System for the Sld Cherenkov Ring Imaging Detector",
abstract = "The front end electronics and data acquisition system for the SLD barrel Cherenkov Ring Imaging Detector (CRID) are described. This electronics must provide a 1 {\%} charge division measurement with a maximum acceptable noise level of 2000 electrons (rms). Noise and system performance results are presented for the initial SLD engineering run data.",
author = "K. Abe and K. Hasegawa and F. Suekane and H. Yuta and S. Dasu and S. Dolinsky and W. Dunwoodie and G. Hallewell and J. Hoeflich and H. Kawahara and Youngjoon Kwon and Leith, {D. W.G.S.} and Marshall, {D. M.} and D. Muller and T. Nagamine and G. Oxoby and Pavel, {T. J.} and B. Ratcliff and P. Rensing and D. Schultz and S. Shapiro and C. Simopoulos and E. Solodov and P. Stiles and N. Toge and J. Va'vra and Williams, {S. H.}",
year = "1992",
month = "1",
day = "1",
doi = "10.1109/23.159728",
language = "English",
volume = "39",
pages = "897--900",
journal = "IEEE Transactions on Nuclear Science",
issn = "0018-9499",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "4",

}

Abe, K, Hasegawa, K, Suekane, F, Yuta, H, Dasu, S, Dolinsky, S, Dunwoodie, W, Hallewell, G, Hoeflich, J, Kawahara, H, Kwon, Y, Leith, DWGS, Marshall, DM, Muller, D, Nagamine, T, Oxoby, G, Pavel, TJ, Ratcliff, B, Rensing, P, Schultz, D, Shapiro, S, Simopoulos, C, Solodov, E, Stiles, P, Toge, N, Va'vra, J & Williams, SH 1992, 'Performance of the Front End Electronics and Data Acquisition System for the Sld Cherenkov Ring Imaging Detector', IEEE Transactions on Nuclear Science, vol. 39, no. 4, pp. 897-900. https://doi.org/10.1109/23.159728

Performance of the Front End Electronics and Data Acquisition System for the Sld Cherenkov Ring Imaging Detector. / Abe, K.; Hasegawa, K.; Suekane, F.; Yuta, H.; Dasu, S.; Dolinsky, S.; Dunwoodie, W.; Hallewell, G.; Hoeflich, J.; Kawahara, H.; Kwon, Youngjoon; Leith, D. W.G.S.; Marshall, D. M.; Muller, D.; Nagamine, T.; Oxoby, G.; Pavel, T. J.; Ratcliff, B.; Rensing, P.; Schultz, D.; Shapiro, S.; Simopoulos, C.; Solodov, E.; Stiles, P.; Toge, N.; Va'vra, J.; Williams, S. H.

In: IEEE Transactions on Nuclear Science, Vol. 39, No. 4, 01.01.1992, p. 897-900.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Performance of the Front End Electronics and Data Acquisition System for the Sld Cherenkov Ring Imaging Detector

AU - Abe, K.

AU - Hasegawa, K.

AU - Suekane, F.

AU - Yuta, H.

AU - Dasu, S.

AU - Dolinsky, S.

AU - Dunwoodie, W.

AU - Hallewell, G.

AU - Hoeflich, J.

AU - Kawahara, H.

AU - Kwon, Youngjoon

AU - Leith, D. W.G.S.

AU - Marshall, D. M.

AU - Muller, D.

AU - Nagamine, T.

AU - Oxoby, G.

AU - Pavel, T. J.

AU - Ratcliff, B.

AU - Rensing, P.

AU - Schultz, D.

AU - Shapiro, S.

AU - Simopoulos, C.

AU - Solodov, E.

AU - Stiles, P.

AU - Toge, N.

AU - Va'vra, J.

AU - Williams, S. H.

PY - 1992/1/1

Y1 - 1992/1/1

N2 - The front end electronics and data acquisition system for the SLD barrel Cherenkov Ring Imaging Detector (CRID) are described. This electronics must provide a 1 % charge division measurement with a maximum acceptable noise level of 2000 electrons (rms). Noise and system performance results are presented for the initial SLD engineering run data.

AB - The front end electronics and data acquisition system for the SLD barrel Cherenkov Ring Imaging Detector (CRID) are described. This electronics must provide a 1 % charge division measurement with a maximum acceptable noise level of 2000 electrons (rms). Noise and system performance results are presented for the initial SLD engineering run data.

UR - http://www.scopus.com/inward/record.url?scp=0026902678&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026902678&partnerID=8YFLogxK

U2 - 10.1109/23.159728

DO - 10.1109/23.159728

M3 - Article

VL - 39

SP - 897

EP - 900

JO - IEEE Transactions on Nuclear Science

JF - IEEE Transactions on Nuclear Science

SN - 0018-9499

IS - 4

ER -