Physiological response of building occupants based on their activity and the indoor environmental quality condition changes

Jimin Kim, Minjin Kong, Taehoon Hong, Kwangbok Jeong, Minhyun Lee

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

This study aimed to analyze the physiological response (i.e., blood pressure) of building occupants based on the 22 subjects’ activity and the Indoor environmental quality (IEQ) condition (i.e., carbon dioxide (CO2) concentration and operative temperature) changes. The experiment was designed with three scenarios to simulate the IEQ condition changes. In each scenario, six cognitive tasks that simulate office work were conducted by the subjects to determine their activity that cause work stress. The paired-t test was conducted to analyze the building occupants’ physiological response by scenario. As a result, with a low CO2 concentration (below 1000 ppm), the subjects maintained homeostasis well under work stress. It was difficult to maintain homeostasis, however, with a high CO2 concentration (above 2000 ppm): When the subjects were under work stress, they showed different responses compared to those of the seated state. Homeostasis was affected by stress, according to the IEQ condition changes. The unacceptable condition and work stress were particularly dangerous for the hypertensive (i.e., above 140 mmHg systolic blood pressure) subjects. For the maintenance of homeostasis of occupants, a low CO2 concentration (below 1000 ppm) should be kept, and work stress above a certain level should be avoided. The building's mechanical system designer and facility manager can manage the IEQ condition considering the building occupants’ physiological responses, which can be used as an IEQ condition management guideline for health.

Original languageEnglish
Pages (from-to)96-103
Number of pages8
JournalBuilding and Environment
Volume145
DOIs
Publication statusPublished - 2018 Nov 1

Fingerprint

Blood pressure
environmental quality
physiological response
homeostasis
building
Carbon dioxide
scenario
Managers
Health
blood
office work
Experiments
Temperature
carbon dioxide
manager
cause
experiment
health
management
temperature

All Science Journal Classification (ASJC) codes

  • Environmental Engineering
  • Civil and Structural Engineering
  • Geography, Planning and Development
  • Building and Construction

Cite this

@article{b7abb5263b9549ebb9a5d82858f36c9e,
title = "Physiological response of building occupants based on their activity and the indoor environmental quality condition changes",
abstract = "This study aimed to analyze the physiological response (i.e., blood pressure) of building occupants based on the 22 subjects’ activity and the Indoor environmental quality (IEQ) condition (i.e., carbon dioxide (CO2) concentration and operative temperature) changes. The experiment was designed with three scenarios to simulate the IEQ condition changes. In each scenario, six cognitive tasks that simulate office work were conducted by the subjects to determine their activity that cause work stress. The paired-t test was conducted to analyze the building occupants’ physiological response by scenario. As a result, with a low CO2 concentration (below 1000 ppm), the subjects maintained homeostasis well under work stress. It was difficult to maintain homeostasis, however, with a high CO2 concentration (above 2000 ppm): When the subjects were under work stress, they showed different responses compared to those of the seated state. Homeostasis was affected by stress, according to the IEQ condition changes. The unacceptable condition and work stress were particularly dangerous for the hypertensive (i.e., above 140 mmHg systolic blood pressure) subjects. For the maintenance of homeostasis of occupants, a low CO2 concentration (below 1000 ppm) should be kept, and work stress above a certain level should be avoided. The building's mechanical system designer and facility manager can manage the IEQ condition considering the building occupants’ physiological responses, which can be used as an IEQ condition management guideline for health.",
author = "Jimin Kim and Minjin Kong and Taehoon Hong and Kwangbok Jeong and Minhyun Lee",
year = "2018",
month = "11",
day = "1",
doi = "10.1016/j.buildenv.2018.09.018",
language = "English",
volume = "145",
pages = "96--103",
journal = "Building and Environment",
issn = "0360-1323",
publisher = "Elsevier BV",

}

Physiological response of building occupants based on their activity and the indoor environmental quality condition changes. / Kim, Jimin; Kong, Minjin; Hong, Taehoon; Jeong, Kwangbok; Lee, Minhyun.

In: Building and Environment, Vol. 145, 01.11.2018, p. 96-103.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Physiological response of building occupants based on their activity and the indoor environmental quality condition changes

AU - Kim, Jimin

AU - Kong, Minjin

AU - Hong, Taehoon

AU - Jeong, Kwangbok

AU - Lee, Minhyun

PY - 2018/11/1

Y1 - 2018/11/1

N2 - This study aimed to analyze the physiological response (i.e., blood pressure) of building occupants based on the 22 subjects’ activity and the Indoor environmental quality (IEQ) condition (i.e., carbon dioxide (CO2) concentration and operative temperature) changes. The experiment was designed with three scenarios to simulate the IEQ condition changes. In each scenario, six cognitive tasks that simulate office work were conducted by the subjects to determine their activity that cause work stress. The paired-t test was conducted to analyze the building occupants’ physiological response by scenario. As a result, with a low CO2 concentration (below 1000 ppm), the subjects maintained homeostasis well under work stress. It was difficult to maintain homeostasis, however, with a high CO2 concentration (above 2000 ppm): When the subjects were under work stress, they showed different responses compared to those of the seated state. Homeostasis was affected by stress, according to the IEQ condition changes. The unacceptable condition and work stress were particularly dangerous for the hypertensive (i.e., above 140 mmHg systolic blood pressure) subjects. For the maintenance of homeostasis of occupants, a low CO2 concentration (below 1000 ppm) should be kept, and work stress above a certain level should be avoided. The building's mechanical system designer and facility manager can manage the IEQ condition considering the building occupants’ physiological responses, which can be used as an IEQ condition management guideline for health.

AB - This study aimed to analyze the physiological response (i.e., blood pressure) of building occupants based on the 22 subjects’ activity and the Indoor environmental quality (IEQ) condition (i.e., carbon dioxide (CO2) concentration and operative temperature) changes. The experiment was designed with three scenarios to simulate the IEQ condition changes. In each scenario, six cognitive tasks that simulate office work were conducted by the subjects to determine their activity that cause work stress. The paired-t test was conducted to analyze the building occupants’ physiological response by scenario. As a result, with a low CO2 concentration (below 1000 ppm), the subjects maintained homeostasis well under work stress. It was difficult to maintain homeostasis, however, with a high CO2 concentration (above 2000 ppm): When the subjects were under work stress, they showed different responses compared to those of the seated state. Homeostasis was affected by stress, according to the IEQ condition changes. The unacceptable condition and work stress were particularly dangerous for the hypertensive (i.e., above 140 mmHg systolic blood pressure) subjects. For the maintenance of homeostasis of occupants, a low CO2 concentration (below 1000 ppm) should be kept, and work stress above a certain level should be avoided. The building's mechanical system designer and facility manager can manage the IEQ condition considering the building occupants’ physiological responses, which can be used as an IEQ condition management guideline for health.

UR - http://www.scopus.com/inward/record.url?scp=85053333924&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85053333924&partnerID=8YFLogxK

U2 - 10.1016/j.buildenv.2018.09.018

DO - 10.1016/j.buildenv.2018.09.018

M3 - Article

VL - 145

SP - 96

EP - 103

JO - Building and Environment

JF - Building and Environment

SN - 0360-1323

ER -