Real-time measurement of submicron aerosol particles having a log-normal size distribution by simultaneously using unipolar diffusion charger and unipolar field charger

D. Park, S. Kim, M. An, Jungho Hwang

Research output: Contribution to journalArticle

21 Citations (Scopus)

Abstract

Recently, Park et al. [(2007). Development and performance test of a unipolar diffusion charger for real-time measurements of submicron aerosol particles having a log-normal size distribution. Journal of Aerosol Science, 38, 420-430] have introduced a methodology for performing simple and fast measurements of submicron aerosol particles having a log-normal size distribution, using a unipolar diffusion charger, an electrometer, and a condensation particle counter (CPC). The methodology can be applied to particles of 30-700 nm and requires an assumption of their geometric standard deviation in size. In this paper we propose a much cheaper but faster method which involves substituting a unipolar field charger and another electrometer for the CPC. With the data obtained using this dual-charger system, we developed a data inversion algorithm and estimated the particle size distribution by minimizing the differences between the measured aerosol currents and the calculated values. To compare the size distribution with the data measured using a scanning mobility particle sizer (SMPS), sodium chloride (NaCl) particles smaller than 0.1 μ m in diameter, and dioctyl sebacate (DOS) particles with a diameter of 0.1-0.7 μ m, were used. The estimated results for the NaCl and DOS particles were within 10% of the data measured with the SMPS, while a 33% deviation from the SMPS results was obtained in Park et al. [(2007). Development and performance test of a unipolar diffusion charger for real-time measurements of submicron aerosol particles having a log-normal size distribution. Journal of Aerosol Science, 38, 420-430]. Furthermore, the detection time obtained with the use of our dual-charger system was faster (< 3 s) than the 5 s obtained by Park et al. [(2007). Development and performance test of a unipolar diffusion charger for real-time measurements of submicron aerosol particles having a log-normal size distribution. Journal of Aerosol Science, 38, 420-430].

Original languageEnglish
Pages (from-to)1240-1245
Number of pages6
JournalJournal of Aerosol Science
Volume38
Issue number12
DOIs
Publication statusPublished - 2007 Jan 1

Fingerprint

Time measurement
Aerosols
Particles (particulate matter)
aerosol
Electrometers
Radiation counters
Scanning
Condensation
condensation
particle
data inversion
Sodium chloride
methodology
Sodium Chloride
Particle size analysis
sodium chloride
particle size

All Science Journal Classification (ASJC) codes

  • Environmental Chemistry
  • Materials Science(all)
  • Pollution

Cite this

@article{fba67ee7979743fc8e7701ad93d665cd,
title = "Real-time measurement of submicron aerosol particles having a log-normal size distribution by simultaneously using unipolar diffusion charger and unipolar field charger",
abstract = "Recently, Park et al. [(2007). Development and performance test of a unipolar diffusion charger for real-time measurements of submicron aerosol particles having a log-normal size distribution. Journal of Aerosol Science, 38, 420-430] have introduced a methodology for performing simple and fast measurements of submicron aerosol particles having a log-normal size distribution, using a unipolar diffusion charger, an electrometer, and a condensation particle counter (CPC). The methodology can be applied to particles of 30-700 nm and requires an assumption of their geometric standard deviation in size. In this paper we propose a much cheaper but faster method which involves substituting a unipolar field charger and another electrometer for the CPC. With the data obtained using this dual-charger system, we developed a data inversion algorithm and estimated the particle size distribution by minimizing the differences between the measured aerosol currents and the calculated values. To compare the size distribution with the data measured using a scanning mobility particle sizer (SMPS), sodium chloride (NaCl) particles smaller than 0.1 μ m in diameter, and dioctyl sebacate (DOS) particles with a diameter of 0.1-0.7 μ m, were used. The estimated results for the NaCl and DOS particles were within 10{\%} of the data measured with the SMPS, while a 33{\%} deviation from the SMPS results was obtained in Park et al. [(2007). Development and performance test of a unipolar diffusion charger for real-time measurements of submicron aerosol particles having a log-normal size distribution. Journal of Aerosol Science, 38, 420-430]. Furthermore, the detection time obtained with the use of our dual-charger system was faster (< 3 s) than the 5 s obtained by Park et al. [(2007). Development and performance test of a unipolar diffusion charger for real-time measurements of submicron aerosol particles having a log-normal size distribution. Journal of Aerosol Science, 38, 420-430].",
author = "D. Park and S. Kim and M. An and Jungho Hwang",
year = "2007",
month = "1",
day = "1",
doi = "10.1016/j.jaerosci.2007.09.002",
language = "English",
volume = "38",
pages = "1240--1245",
journal = "Journal of Aerosol Science",
issn = "0021-8502",
publisher = "Elsevier Limited",
number = "12",

}

TY - JOUR

T1 - Real-time measurement of submicron aerosol particles having a log-normal size distribution by simultaneously using unipolar diffusion charger and unipolar field charger

AU - Park, D.

AU - Kim, S.

AU - An, M.

AU - Hwang, Jungho

PY - 2007/1/1

Y1 - 2007/1/1

N2 - Recently, Park et al. [(2007). Development and performance test of a unipolar diffusion charger for real-time measurements of submicron aerosol particles having a log-normal size distribution. Journal of Aerosol Science, 38, 420-430] have introduced a methodology for performing simple and fast measurements of submicron aerosol particles having a log-normal size distribution, using a unipolar diffusion charger, an electrometer, and a condensation particle counter (CPC). The methodology can be applied to particles of 30-700 nm and requires an assumption of their geometric standard deviation in size. In this paper we propose a much cheaper but faster method which involves substituting a unipolar field charger and another electrometer for the CPC. With the data obtained using this dual-charger system, we developed a data inversion algorithm and estimated the particle size distribution by minimizing the differences between the measured aerosol currents and the calculated values. To compare the size distribution with the data measured using a scanning mobility particle sizer (SMPS), sodium chloride (NaCl) particles smaller than 0.1 μ m in diameter, and dioctyl sebacate (DOS) particles with a diameter of 0.1-0.7 μ m, were used. The estimated results for the NaCl and DOS particles were within 10% of the data measured with the SMPS, while a 33% deviation from the SMPS results was obtained in Park et al. [(2007). Development and performance test of a unipolar diffusion charger for real-time measurements of submicron aerosol particles having a log-normal size distribution. Journal of Aerosol Science, 38, 420-430]. Furthermore, the detection time obtained with the use of our dual-charger system was faster (< 3 s) than the 5 s obtained by Park et al. [(2007). Development and performance test of a unipolar diffusion charger for real-time measurements of submicron aerosol particles having a log-normal size distribution. Journal of Aerosol Science, 38, 420-430].

AB - Recently, Park et al. [(2007). Development and performance test of a unipolar diffusion charger for real-time measurements of submicron aerosol particles having a log-normal size distribution. Journal of Aerosol Science, 38, 420-430] have introduced a methodology for performing simple and fast measurements of submicron aerosol particles having a log-normal size distribution, using a unipolar diffusion charger, an electrometer, and a condensation particle counter (CPC). The methodology can be applied to particles of 30-700 nm and requires an assumption of their geometric standard deviation in size. In this paper we propose a much cheaper but faster method which involves substituting a unipolar field charger and another electrometer for the CPC. With the data obtained using this dual-charger system, we developed a data inversion algorithm and estimated the particle size distribution by minimizing the differences between the measured aerosol currents and the calculated values. To compare the size distribution with the data measured using a scanning mobility particle sizer (SMPS), sodium chloride (NaCl) particles smaller than 0.1 μ m in diameter, and dioctyl sebacate (DOS) particles with a diameter of 0.1-0.7 μ m, were used. The estimated results for the NaCl and DOS particles were within 10% of the data measured with the SMPS, while a 33% deviation from the SMPS results was obtained in Park et al. [(2007). Development and performance test of a unipolar diffusion charger for real-time measurements of submicron aerosol particles having a log-normal size distribution. Journal of Aerosol Science, 38, 420-430]. Furthermore, the detection time obtained with the use of our dual-charger system was faster (< 3 s) than the 5 s obtained by Park et al. [(2007). Development and performance test of a unipolar diffusion charger for real-time measurements of submicron aerosol particles having a log-normal size distribution. Journal of Aerosol Science, 38, 420-430].

UR - http://www.scopus.com/inward/record.url?scp=36248949587&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=36248949587&partnerID=8YFLogxK

U2 - 10.1016/j.jaerosci.2007.09.002

DO - 10.1016/j.jaerosci.2007.09.002

M3 - Article

AN - SCOPUS:36248949587

VL - 38

SP - 1240

EP - 1245

JO - Journal of Aerosol Science

JF - Journal of Aerosol Science

SN - 0021-8502

IS - 12

ER -