Serious complication of cement augmentation for damaged pilot hole

Moon Young Jung, DongAh Shin, In Bo Hahn, Tae Gon Kim, Ryoong Huh, Sang Sup Chung

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

Polymethl methacrylate (PMMA) screw reinforcement is frequently used in osteoporotic bone as well as in damaged pilot holes. However, PMMA use can be dangerous, since the amount of applied cement is uncontrolled. A 47-year-old male with traumatic cervical spondylolisthesis at C6-7 underwent anterior cervical plate fixation. During repeated drilling and tapping for false trajectory correction, a pilot hole was damaged. Although it was an unconventional method, PMMA augmentation was tried. However, PMMA was accidentally injected to the cervical spinal cord owing to lack of fluoroscopic guidance. The PMMA was surgically removed after corpectomy and durotomy. The patient had left side hemiparesis (Grade 2/5) immediately post operation. The patient improved spontaneously (Grade 4/5) except for 4th and 5th digit extension. Here, we report a rare complication of PMMA extrusion in the spinal cord during a damaged pilot hole injection, which has not previously been described.

Original languageEnglish
Pages (from-to)466-468
Number of pages3
JournalYonsei medical journal
Volume51
Issue number3
DOIs
Publication statusPublished - 2010 May 1

Fingerprint

Methacrylates
Spondylolisthesis
Paresis
Spinal Cord
Bone and Bones

All Science Journal Classification (ASJC) codes

  • Medicine(all)

Cite this

Jung, Moon Young ; Shin, DongAh ; Hahn, In Bo ; Kim, Tae Gon ; Huh, Ryoong ; Chung, Sang Sup. / Serious complication of cement augmentation for damaged pilot hole. In: Yonsei medical journal. 2010 ; Vol. 51, No. 3. pp. 466-468.
@article{c54d14befb5540e189e6deafbb4327be,
title = "Serious complication of cement augmentation for damaged pilot hole",
abstract = "Polymethl methacrylate (PMMA) screw reinforcement is frequently used in osteoporotic bone as well as in damaged pilot holes. However, PMMA use can be dangerous, since the amount of applied cement is uncontrolled. A 47-year-old male with traumatic cervical spondylolisthesis at C6-7 underwent anterior cervical plate fixation. During repeated drilling and tapping for false trajectory correction, a pilot hole was damaged. Although it was an unconventional method, PMMA augmentation was tried. However, PMMA was accidentally injected to the cervical spinal cord owing to lack of fluoroscopic guidance. The PMMA was surgically removed after corpectomy and durotomy. The patient had left side hemiparesis (Grade 2/5) immediately post operation. The patient improved spontaneously (Grade 4/5) except for 4th and 5th digit extension. Here, we report a rare complication of PMMA extrusion in the spinal cord during a damaged pilot hole injection, which has not previously been described.",
author = "Jung, {Moon Young} and DongAh Shin and Hahn, {In Bo} and Kim, {Tae Gon} and Ryoong Huh and Chung, {Sang Sup}",
year = "2010",
month = "5",
day = "1",
doi = "10.3349/ymj.2010.51.3.466",
language = "English",
volume = "51",
pages = "466--468",
journal = "Yonsei Medical Journal",
issn = "0513-5796",
publisher = "Yonsei University College of Medicine",
number = "3",

}

Serious complication of cement augmentation for damaged pilot hole. / Jung, Moon Young; Shin, DongAh; Hahn, In Bo; Kim, Tae Gon; Huh, Ryoong; Chung, Sang Sup.

In: Yonsei medical journal, Vol. 51, No. 3, 01.05.2010, p. 466-468.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Serious complication of cement augmentation for damaged pilot hole

AU - Jung, Moon Young

AU - Shin, DongAh

AU - Hahn, In Bo

AU - Kim, Tae Gon

AU - Huh, Ryoong

AU - Chung, Sang Sup

PY - 2010/5/1

Y1 - 2010/5/1

N2 - Polymethl methacrylate (PMMA) screw reinforcement is frequently used in osteoporotic bone as well as in damaged pilot holes. However, PMMA use can be dangerous, since the amount of applied cement is uncontrolled. A 47-year-old male with traumatic cervical spondylolisthesis at C6-7 underwent anterior cervical plate fixation. During repeated drilling and tapping for false trajectory correction, a pilot hole was damaged. Although it was an unconventional method, PMMA augmentation was tried. However, PMMA was accidentally injected to the cervical spinal cord owing to lack of fluoroscopic guidance. The PMMA was surgically removed after corpectomy and durotomy. The patient had left side hemiparesis (Grade 2/5) immediately post operation. The patient improved spontaneously (Grade 4/5) except for 4th and 5th digit extension. Here, we report a rare complication of PMMA extrusion in the spinal cord during a damaged pilot hole injection, which has not previously been described.

AB - Polymethl methacrylate (PMMA) screw reinforcement is frequently used in osteoporotic bone as well as in damaged pilot holes. However, PMMA use can be dangerous, since the amount of applied cement is uncontrolled. A 47-year-old male with traumatic cervical spondylolisthesis at C6-7 underwent anterior cervical plate fixation. During repeated drilling and tapping for false trajectory correction, a pilot hole was damaged. Although it was an unconventional method, PMMA augmentation was tried. However, PMMA was accidentally injected to the cervical spinal cord owing to lack of fluoroscopic guidance. The PMMA was surgically removed after corpectomy and durotomy. The patient had left side hemiparesis (Grade 2/5) immediately post operation. The patient improved spontaneously (Grade 4/5) except for 4th and 5th digit extension. Here, we report a rare complication of PMMA extrusion in the spinal cord during a damaged pilot hole injection, which has not previously been described.

UR - http://www.scopus.com/inward/record.url?scp=77954278626&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77954278626&partnerID=8YFLogxK

U2 - 10.3349/ymj.2010.51.3.466

DO - 10.3349/ymj.2010.51.3.466

M3 - Article

VL - 51

SP - 466

EP - 468

JO - Yonsei Medical Journal

JF - Yonsei Medical Journal

SN - 0513-5796

IS - 3

ER -