Shear resistance characteristic and ductility of Y-type perfobond rib shear connector

Sang Hyo Kim, Se Jun Park, Won Ho Heo, Chi Young Jung

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

This study evaluates behavior of the Y-type perfobond rib shear connector proposed by Kim et al. (2013). In addition, an empirical shear resistance formula is developed based on push-out tests. Various types of the proposed Y-type perfobond rib shear connectors are examined to evaluate the effects of design variables such as concrete strength, number of transverse rebars, and thickness of rib. It is verified that higher concrete strength increases shear resistance but decreases ductility. Placing transverse rebars significantly increases both the shear resistance and ductility. As the thickness of the ribs increases, the shear resistance increases but the ductility decreases. The experimental results indicate that a Y-type perfobond rib shear connector has higher shear resistance and ductility than the conventional stud shear connector. The effects of the end bearing resistance, resistance by transverse rebars, concrete dowel resistance by holes, and concrete dowel resistance by Y-shape ribs on the shear resistance are estimated empirically based on the push-out test results and the additional push-out test results by Kim et al. (2013). An empirical shear resistance formula is suggested to estimate the shear resistance of a Y-type perfobond shear connector for design purposes. The newly developed shear resistance formula is in reasonable agreement with the experimental results because the average ratio of measured shear resistance to estimated shear resistance is 1.024.

Original languageEnglish
Pages (from-to)497-517
Number of pages21
JournalSteel and Composite Structures
Volume18
Issue number2
DOIs
Publication statusPublished - 2015 Feb 1

Fingerprint

Ductility
Concretes
Bearings (structural)
Shear strength

All Science Journal Classification (ASJC) codes

  • Civil and Structural Engineering
  • Building and Construction
  • Metals and Alloys

Cite this

Kim, Sang Hyo ; Park, Se Jun ; Heo, Won Ho ; Jung, Chi Young. / Shear resistance characteristic and ductility of Y-type perfobond rib shear connector. In: Steel and Composite Structures. 2015 ; Vol. 18, No. 2. pp. 497-517.
@article{eb2ef24ed23e4b66a0d9f022420b7071,
title = "Shear resistance characteristic and ductility of Y-type perfobond rib shear connector",
abstract = "This study evaluates behavior of the Y-type perfobond rib shear connector proposed by Kim et al. (2013). In addition, an empirical shear resistance formula is developed based on push-out tests. Various types of the proposed Y-type perfobond rib shear connectors are examined to evaluate the effects of design variables such as concrete strength, number of transverse rebars, and thickness of rib. It is verified that higher concrete strength increases shear resistance but decreases ductility. Placing transverse rebars significantly increases both the shear resistance and ductility. As the thickness of the ribs increases, the shear resistance increases but the ductility decreases. The experimental results indicate that a Y-type perfobond rib shear connector has higher shear resistance and ductility than the conventional stud shear connector. The effects of the end bearing resistance, resistance by transverse rebars, concrete dowel resistance by holes, and concrete dowel resistance by Y-shape ribs on the shear resistance are estimated empirically based on the push-out test results and the additional push-out test results by Kim et al. (2013). An empirical shear resistance formula is suggested to estimate the shear resistance of a Y-type perfobond shear connector for design purposes. The newly developed shear resistance formula is in reasonable agreement with the experimental results because the average ratio of measured shear resistance to estimated shear resistance is 1.024.",
author = "Kim, {Sang Hyo} and Park, {Se Jun} and Heo, {Won Ho} and Jung, {Chi Young}",
year = "2015",
month = "2",
day = "1",
doi = "10.12989/scs.2015.18.2.497",
language = "English",
volume = "18",
pages = "497--517",
journal = "Steel and Composite Structures",
issn = "1229-9367",
publisher = "Techno Press",
number = "2",

}

Shear resistance characteristic and ductility of Y-type perfobond rib shear connector. / Kim, Sang Hyo; Park, Se Jun; Heo, Won Ho; Jung, Chi Young.

In: Steel and Composite Structures, Vol. 18, No. 2, 01.02.2015, p. 497-517.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Shear resistance characteristic and ductility of Y-type perfobond rib shear connector

AU - Kim, Sang Hyo

AU - Park, Se Jun

AU - Heo, Won Ho

AU - Jung, Chi Young

PY - 2015/2/1

Y1 - 2015/2/1

N2 - This study evaluates behavior of the Y-type perfobond rib shear connector proposed by Kim et al. (2013). In addition, an empirical shear resistance formula is developed based on push-out tests. Various types of the proposed Y-type perfobond rib shear connectors are examined to evaluate the effects of design variables such as concrete strength, number of transverse rebars, and thickness of rib. It is verified that higher concrete strength increases shear resistance but decreases ductility. Placing transverse rebars significantly increases both the shear resistance and ductility. As the thickness of the ribs increases, the shear resistance increases but the ductility decreases. The experimental results indicate that a Y-type perfobond rib shear connector has higher shear resistance and ductility than the conventional stud shear connector. The effects of the end bearing resistance, resistance by transverse rebars, concrete dowel resistance by holes, and concrete dowel resistance by Y-shape ribs on the shear resistance are estimated empirically based on the push-out test results and the additional push-out test results by Kim et al. (2013). An empirical shear resistance formula is suggested to estimate the shear resistance of a Y-type perfobond shear connector for design purposes. The newly developed shear resistance formula is in reasonable agreement with the experimental results because the average ratio of measured shear resistance to estimated shear resistance is 1.024.

AB - This study evaluates behavior of the Y-type perfobond rib shear connector proposed by Kim et al. (2013). In addition, an empirical shear resistance formula is developed based on push-out tests. Various types of the proposed Y-type perfobond rib shear connectors are examined to evaluate the effects of design variables such as concrete strength, number of transverse rebars, and thickness of rib. It is verified that higher concrete strength increases shear resistance but decreases ductility. Placing transverse rebars significantly increases both the shear resistance and ductility. As the thickness of the ribs increases, the shear resistance increases but the ductility decreases. The experimental results indicate that a Y-type perfobond rib shear connector has higher shear resistance and ductility than the conventional stud shear connector. The effects of the end bearing resistance, resistance by transverse rebars, concrete dowel resistance by holes, and concrete dowel resistance by Y-shape ribs on the shear resistance are estimated empirically based on the push-out test results and the additional push-out test results by Kim et al. (2013). An empirical shear resistance formula is suggested to estimate the shear resistance of a Y-type perfobond shear connector for design purposes. The newly developed shear resistance formula is in reasonable agreement with the experimental results because the average ratio of measured shear resistance to estimated shear resistance is 1.024.

UR - http://www.scopus.com/inward/record.url?scp=84930799043&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84930799043&partnerID=8YFLogxK

U2 - 10.12989/scs.2015.18.2.497

DO - 10.12989/scs.2015.18.2.497

M3 - Article

AN - SCOPUS:84930799043

VL - 18

SP - 497

EP - 517

JO - Steel and Composite Structures

JF - Steel and Composite Structures

SN - 1229-9367

IS - 2

ER -