Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes: An in-silico modeling study

Jun Seop Song, Young Seon Lee, Minki Hwang, Jung Kee Lee, Changyong Li, Boyoung Joung, Moon Hyoung Lee, Eun Bo Shim, Hui Nam Pak

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Although 3D-complex fractionated atrial electrogram (CFAE) mapping is useful in radiofrequency catheter ablation for persistent atrial fibrillation (AF), the directions and configuration of the bipolar electrodes may affect the electrogram. This study aimed to compare the spatial reproducibility of CFAE by changing the catheter orientations and electrode distance in an in-silico left atrium (LA). We conducted this study by importing the heart CT image of a patient with AF into a 3D-homogeneous human LA model. Electrogram morphology, CFAE-cycle lengths (CLs) were compared for 16 different orientations of a virtual bipolar conventional catheter (conv-cath: size 3.5 mm, inter-electrode distance 4.75 mm). Additionally, the spatial correlations of CFAE-CLs and the percentage of consistent sites with CFAE-CL<120 ms were analyzed. The results from the conv-cath were compared with that obtained using a mini catheter (mini-cath: size 1 mm, inter-electrode distance 2.5 mm). Depending on the catheter orientation, the electrogram morphology and CFAE-CLs varied (conv-cath: 11.5±0.7% variation, mini-cath: 7.1±1.2% variation), however the mini-cath produced less variation of CFAE-CL than conv-cath (p<0.001). There were moderate spatial correlations among CFAE-CL measured at 16 orientations (conv-cath: r=0.3055±0.2194 vs. mini-cath: 0.6074±0.0733, p<0.001). Additionally, the ratio of consistent CFAE sites was higher for mini catheter than conventional one (38.3±4.6% vs. 22.3±1.4%, p<0.05). Electrograms and CFAE distribution are affected by catheter orientation and electrode configuration in the in-silico LA model. However, there was moderate spatial consistency of CFAE areas, and narrowly spaced bipolar catheters were less influenced by catheter direction than conventional catheters.

Original languageEnglish
Pages (from-to)507-514
Number of pages8
JournalKorean Journal of Physiology and Pharmacology
Volume20
Issue number5
DOIs
Publication statusPublished - 2016 Sep

Fingerprint

Cardiac Electrophysiologic Techniques
Computer Simulation
Electrodes
Catheters
Heart Atria
Atrial Fibrillation
Direction compound
Catheter Ablation

All Science Journal Classification (ASJC) codes

  • Physiology
  • Pharmacology

Cite this

Song, Jun Seop ; Lee, Young Seon ; Hwang, Minki ; Lee, Jung Kee ; Li, Changyong ; Joung, Boyoung ; Lee, Moon Hyoung ; Shim, Eun Bo ; Pak, Hui Nam. / Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes : An in-silico modeling study. In: Korean Journal of Physiology and Pharmacology. 2016 ; Vol. 20, No. 5. pp. 507-514.
@article{64a0477f7e4347b3b1eb999410be0447,
title = "Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes: An in-silico modeling study",
abstract = "Although 3D-complex fractionated atrial electrogram (CFAE) mapping is useful in radiofrequency catheter ablation for persistent atrial fibrillation (AF), the directions and configuration of the bipolar electrodes may affect the electrogram. This study aimed to compare the spatial reproducibility of CFAE by changing the catheter orientations and electrode distance in an in-silico left atrium (LA). We conducted this study by importing the heart CT image of a patient with AF into a 3D-homogeneous human LA model. Electrogram morphology, CFAE-cycle lengths (CLs) were compared for 16 different orientations of a virtual bipolar conventional catheter (conv-cath: size 3.5 mm, inter-electrode distance 4.75 mm). Additionally, the spatial correlations of CFAE-CLs and the percentage of consistent sites with CFAE-CL<120 ms were analyzed. The results from the conv-cath were compared with that obtained using a mini catheter (mini-cath: size 1 mm, inter-electrode distance 2.5 mm). Depending on the catheter orientation, the electrogram morphology and CFAE-CLs varied (conv-cath: 11.5±0.7{\%} variation, mini-cath: 7.1±1.2{\%} variation), however the mini-cath produced less variation of CFAE-CL than conv-cath (p<0.001). There were moderate spatial correlations among CFAE-CL measured at 16 orientations (conv-cath: r=0.3055±0.2194 vs. mini-cath: 0.6074±0.0733, p<0.001). Additionally, the ratio of consistent CFAE sites was higher for mini catheter than conventional one (38.3±4.6{\%} vs. 22.3±1.4{\%}, p<0.05). Electrograms and CFAE distribution are affected by catheter orientation and electrode configuration in the in-silico LA model. However, there was moderate spatial consistency of CFAE areas, and narrowly spaced bipolar catheters were less influenced by catheter direction than conventional catheters.",
author = "Song, {Jun Seop} and Lee, {Young Seon} and Minki Hwang and Lee, {Jung Kee} and Changyong Li and Boyoung Joung and Lee, {Moon Hyoung} and Shim, {Eun Bo} and Pak, {Hui Nam}",
year = "2016",
month = "9",
doi = "10.4196/kjpp.2016.20.5.507",
language = "English",
volume = "20",
pages = "507--514",
journal = "Korean Journal of Physiology and Pharmacology",
issn = "1226-4512",
publisher = "Korean Physiological Soc. and Korean Soc. of Pharmacology",
number = "5",

}

Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes : An in-silico modeling study. / Song, Jun Seop; Lee, Young Seon; Hwang, Minki; Lee, Jung Kee; Li, Changyong; Joung, Boyoung; Lee, Moon Hyoung; Shim, Eun Bo; Pak, Hui Nam.

In: Korean Journal of Physiology and Pharmacology, Vol. 20, No. 5, 09.2016, p. 507-514.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes

T2 - An in-silico modeling study

AU - Song, Jun Seop

AU - Lee, Young Seon

AU - Hwang, Minki

AU - Lee, Jung Kee

AU - Li, Changyong

AU - Joung, Boyoung

AU - Lee, Moon Hyoung

AU - Shim, Eun Bo

AU - Pak, Hui Nam

PY - 2016/9

Y1 - 2016/9

N2 - Although 3D-complex fractionated atrial electrogram (CFAE) mapping is useful in radiofrequency catheter ablation for persistent atrial fibrillation (AF), the directions and configuration of the bipolar electrodes may affect the electrogram. This study aimed to compare the spatial reproducibility of CFAE by changing the catheter orientations and electrode distance in an in-silico left atrium (LA). We conducted this study by importing the heart CT image of a patient with AF into a 3D-homogeneous human LA model. Electrogram morphology, CFAE-cycle lengths (CLs) were compared for 16 different orientations of a virtual bipolar conventional catheter (conv-cath: size 3.5 mm, inter-electrode distance 4.75 mm). Additionally, the spatial correlations of CFAE-CLs and the percentage of consistent sites with CFAE-CL<120 ms were analyzed. The results from the conv-cath were compared with that obtained using a mini catheter (mini-cath: size 1 mm, inter-electrode distance 2.5 mm). Depending on the catheter orientation, the electrogram morphology and CFAE-CLs varied (conv-cath: 11.5±0.7% variation, mini-cath: 7.1±1.2% variation), however the mini-cath produced less variation of CFAE-CL than conv-cath (p<0.001). There were moderate spatial correlations among CFAE-CL measured at 16 orientations (conv-cath: r=0.3055±0.2194 vs. mini-cath: 0.6074±0.0733, p<0.001). Additionally, the ratio of consistent CFAE sites was higher for mini catheter than conventional one (38.3±4.6% vs. 22.3±1.4%, p<0.05). Electrograms and CFAE distribution are affected by catheter orientation and electrode configuration in the in-silico LA model. However, there was moderate spatial consistency of CFAE areas, and narrowly spaced bipolar catheters were less influenced by catheter direction than conventional catheters.

AB - Although 3D-complex fractionated atrial electrogram (CFAE) mapping is useful in radiofrequency catheter ablation for persistent atrial fibrillation (AF), the directions and configuration of the bipolar electrodes may affect the electrogram. This study aimed to compare the spatial reproducibility of CFAE by changing the catheter orientations and electrode distance in an in-silico left atrium (LA). We conducted this study by importing the heart CT image of a patient with AF into a 3D-homogeneous human LA model. Electrogram morphology, CFAE-cycle lengths (CLs) were compared for 16 different orientations of a virtual bipolar conventional catheter (conv-cath: size 3.5 mm, inter-electrode distance 4.75 mm). Additionally, the spatial correlations of CFAE-CLs and the percentage of consistent sites with CFAE-CL<120 ms were analyzed. The results from the conv-cath were compared with that obtained using a mini catheter (mini-cath: size 1 mm, inter-electrode distance 2.5 mm). Depending on the catheter orientation, the electrogram morphology and CFAE-CLs varied (conv-cath: 11.5±0.7% variation, mini-cath: 7.1±1.2% variation), however the mini-cath produced less variation of CFAE-CL than conv-cath (p<0.001). There were moderate spatial correlations among CFAE-CL measured at 16 orientations (conv-cath: r=0.3055±0.2194 vs. mini-cath: 0.6074±0.0733, p<0.001). Additionally, the ratio of consistent CFAE sites was higher for mini catheter than conventional one (38.3±4.6% vs. 22.3±1.4%, p<0.05). Electrograms and CFAE distribution are affected by catheter orientation and electrode configuration in the in-silico LA model. However, there was moderate spatial consistency of CFAE areas, and narrowly spaced bipolar catheters were less influenced by catheter direction than conventional catheters.

UR - http://www.scopus.com/inward/record.url?scp=84987749233&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84987749233&partnerID=8YFLogxK

U2 - 10.4196/kjpp.2016.20.5.507

DO - 10.4196/kjpp.2016.20.5.507

M3 - Article

AN - SCOPUS:84987749233

VL - 20

SP - 507

EP - 514

JO - Korean Journal of Physiology and Pharmacology

JF - Korean Journal of Physiology and Pharmacology

SN - 1226-4512

IS - 5

ER -