Abstract

In this study, we designed a moving bed for a radiation therapy system in conjunction with multi robot arms. Kinematic analysis is conducted for workspace which does not interfere with multi robot arms. A tensile force distribution method and optimal z-axis length is considered for minimizing the tensile force in rods.

Original languageEnglish
Title of host publicationASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016
PublisherAmerican Society of Mechanical Engineers
ISBN (Electronic)9780791849880
DOIs
Publication statusPublished - 2016 Jan 1
EventASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016 - Santa Clara, United States
Duration: 2016 Jun 202016 Jun 21

Publication series

NameASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016

Other

OtherASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016
CountryUnited States
CitySanta Clara
Period16/6/2016/6/21

Fingerprint

Radiotherapy
Kinematics
Robots

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Hardware and Architecture
  • Information Systems

Cite this

Kim, D., Park, N. C., Jeong, K. M., & Kim, S. (2016). The design and kinematic analysis of a moving bed for a radiation therapy system. In ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016 (ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016). American Society of Mechanical Engineers. https://doi.org/10.1115/ISPS2016-9604
Kim, Dongwook ; Park, No Cheol ; Jeong, Kyung Min ; Kim, Seungho. / The design and kinematic analysis of a moving bed for a radiation therapy system. ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016. American Society of Mechanical Engineers, 2016. (ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016).
@inproceedings{a39cf312ae784bf08fe7962c2d192ed8,
title = "The design and kinematic analysis of a moving bed for a radiation therapy system",
abstract = "In this study, we designed a moving bed for a radiation therapy system in conjunction with multi robot arms. Kinematic analysis is conducted for workspace which does not interfere with multi robot arms. A tensile force distribution method and optimal z-axis length is considered for minimizing the tensile force in rods.",
author = "Dongwook Kim and Park, {No Cheol} and Jeong, {Kyung Min} and Seungho Kim",
year = "2016",
month = "1",
day = "1",
doi = "10.1115/ISPS2016-9604",
language = "English",
series = "ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016",
publisher = "American Society of Mechanical Engineers",
booktitle = "ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016",

}

Kim, D, Park, NC, Jeong, KM & Kim, S 2016, The design and kinematic analysis of a moving bed for a radiation therapy system. in ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016. ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016, American Society of Mechanical Engineers, ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016, Santa Clara, United States, 16/6/20. https://doi.org/10.1115/ISPS2016-9604

The design and kinematic analysis of a moving bed for a radiation therapy system. / Kim, Dongwook; Park, No Cheol; Jeong, Kyung Min; Kim, Seungho.

ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016. American Society of Mechanical Engineers, 2016. (ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - The design and kinematic analysis of a moving bed for a radiation therapy system

AU - Kim, Dongwook

AU - Park, No Cheol

AU - Jeong, Kyung Min

AU - Kim, Seungho

PY - 2016/1/1

Y1 - 2016/1/1

N2 - In this study, we designed a moving bed for a radiation therapy system in conjunction with multi robot arms. Kinematic analysis is conducted for workspace which does not interfere with multi robot arms. A tensile force distribution method and optimal z-axis length is considered for minimizing the tensile force in rods.

AB - In this study, we designed a moving bed for a radiation therapy system in conjunction with multi robot arms. Kinematic analysis is conducted for workspace which does not interfere with multi robot arms. A tensile force distribution method and optimal z-axis length is considered for minimizing the tensile force in rods.

UR - http://www.scopus.com/inward/record.url?scp=84991743402&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84991743402&partnerID=8YFLogxK

U2 - 10.1115/ISPS2016-9604

DO - 10.1115/ISPS2016-9604

M3 - Conference contribution

AN - SCOPUS:84991743402

T3 - ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016

BT - ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016

PB - American Society of Mechanical Engineers

ER -

Kim D, Park NC, Jeong KM, Kim S. The design and kinematic analysis of a moving bed for a radiation therapy system. In ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016. American Society of Mechanical Engineers. 2016. (ASME 2016 Conference on Information Storage and Processing Systems, ISPS 2016). https://doi.org/10.1115/ISPS2016-9604