The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews

A pilot study

Young Moon Cho, Jung Yul Cha, ChungJu Hwang

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

The aim of this study was to evaluate the effect of the direction and magnitude of the rotation moment to loaded orthodontic miniscrews on stability.In six adult male beagle dogs (12 months old), 36 orthodontic miniscrews were inserted into the mandibular buccal alveolar bone without drilling. Immediately after insertion, 24 miniscrews were loaded with 1- and 2-Ncm nickel titanium (NiTi) coil springs with either a clockwise or counterclockwise rotation moment while 12 miniscrews were left unloaded. Following an observation period of 3 or 12 weeks, the animals were killed and the miniscrews with the surrounding bone were prepared for histomorphometric evaluation. Bone-to-implant contact (BIC) and the ratio of bone volume/total volume (BV/TV) were measured. BIC and BV/TV were statistically compared using the Kruskal-Wallis H and Mann-Whitney U tests.Three of the miniscrews loaded with 2 Ncm counterclockwise rotation moment were lost within 3 weeks. At 12 weeks after insertion, the counterclockwise group showed a statistically significantly lower BIC in comparison with the clockwise group.The results suggest that a rotation moment to loaded orthodontic miniscrews, as well as the direction and magnitude of the rotation moment, can influence miniscrew stability. Counterclockwise rotational moments can be a risk factor impairing miniscrew stability.

Original languageEnglish
Pages (from-to)614-619
Number of pages6
JournalEuropean Journal of Orthodontics
Volume32
Issue number6
DOIs
Publication statusPublished - 2010 Dec 1

Fingerprint

Orthodontics
Bone and Bones
Zygoma
Nonparametric Statistics
Observation
Dogs

All Science Journal Classification (ASJC) codes

  • Orthodontics

Cite this

@article{d4aeeaa17efd4c0f9358452c5a38662c,
title = "The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews: A pilot study",
abstract = "The aim of this study was to evaluate the effect of the direction and magnitude of the rotation moment to loaded orthodontic miniscrews on stability.In six adult male beagle dogs (12 months old), 36 orthodontic miniscrews were inserted into the mandibular buccal alveolar bone without drilling. Immediately after insertion, 24 miniscrews were loaded with 1- and 2-Ncm nickel titanium (NiTi) coil springs with either a clockwise or counterclockwise rotation moment while 12 miniscrews were left unloaded. Following an observation period of 3 or 12 weeks, the animals were killed and the miniscrews with the surrounding bone were prepared for histomorphometric evaluation. Bone-to-implant contact (BIC) and the ratio of bone volume/total volume (BV/TV) were measured. BIC and BV/TV were statistically compared using the Kruskal-Wallis H and Mann-Whitney U tests.Three of the miniscrews loaded with 2 Ncm counterclockwise rotation moment were lost within 3 weeks. At 12 weeks after insertion, the counterclockwise group showed a statistically significantly lower BIC in comparison with the clockwise group.The results suggest that a rotation moment to loaded orthodontic miniscrews, as well as the direction and magnitude of the rotation moment, can influence miniscrew stability. Counterclockwise rotational moments can be a risk factor impairing miniscrew stability.",
author = "Cho, {Young Moon} and Cha, {Jung Yul} and ChungJu Hwang",
year = "2010",
month = "12",
day = "1",
doi = "10.1093/ejo/cjq008",
language = "English",
volume = "32",
pages = "614--619",
journal = "European Journal of Orthodontics",
issn = "0141-5387",
publisher = "Oxford University Press",
number = "6",

}

The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews : A pilot study. / Cho, Young Moon; Cha, Jung Yul; Hwang, ChungJu.

In: European Journal of Orthodontics, Vol. 32, No. 6, 01.12.2010, p. 614-619.

Research output: Contribution to journalArticle

TY - JOUR

T1 - The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews

T2 - A pilot study

AU - Cho, Young Moon

AU - Cha, Jung Yul

AU - Hwang, ChungJu

PY - 2010/12/1

Y1 - 2010/12/1

N2 - The aim of this study was to evaluate the effect of the direction and magnitude of the rotation moment to loaded orthodontic miniscrews on stability.In six adult male beagle dogs (12 months old), 36 orthodontic miniscrews were inserted into the mandibular buccal alveolar bone without drilling. Immediately after insertion, 24 miniscrews were loaded with 1- and 2-Ncm nickel titanium (NiTi) coil springs with either a clockwise or counterclockwise rotation moment while 12 miniscrews were left unloaded. Following an observation period of 3 or 12 weeks, the animals were killed and the miniscrews with the surrounding bone were prepared for histomorphometric evaluation. Bone-to-implant contact (BIC) and the ratio of bone volume/total volume (BV/TV) were measured. BIC and BV/TV were statistically compared using the Kruskal-Wallis H and Mann-Whitney U tests.Three of the miniscrews loaded with 2 Ncm counterclockwise rotation moment were lost within 3 weeks. At 12 weeks after insertion, the counterclockwise group showed a statistically significantly lower BIC in comparison with the clockwise group.The results suggest that a rotation moment to loaded orthodontic miniscrews, as well as the direction and magnitude of the rotation moment, can influence miniscrew stability. Counterclockwise rotational moments can be a risk factor impairing miniscrew stability.

AB - The aim of this study was to evaluate the effect of the direction and magnitude of the rotation moment to loaded orthodontic miniscrews on stability.In six adult male beagle dogs (12 months old), 36 orthodontic miniscrews were inserted into the mandibular buccal alveolar bone without drilling. Immediately after insertion, 24 miniscrews were loaded with 1- and 2-Ncm nickel titanium (NiTi) coil springs with either a clockwise or counterclockwise rotation moment while 12 miniscrews were left unloaded. Following an observation period of 3 or 12 weeks, the animals were killed and the miniscrews with the surrounding bone were prepared for histomorphometric evaluation. Bone-to-implant contact (BIC) and the ratio of bone volume/total volume (BV/TV) were measured. BIC and BV/TV were statistically compared using the Kruskal-Wallis H and Mann-Whitney U tests.Three of the miniscrews loaded with 2 Ncm counterclockwise rotation moment were lost within 3 weeks. At 12 weeks after insertion, the counterclockwise group showed a statistically significantly lower BIC in comparison with the clockwise group.The results suggest that a rotation moment to loaded orthodontic miniscrews, as well as the direction and magnitude of the rotation moment, can influence miniscrew stability. Counterclockwise rotational moments can be a risk factor impairing miniscrew stability.

UR - http://www.scopus.com/inward/record.url?scp=78649543465&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78649543465&partnerID=8YFLogxK

U2 - 10.1093/ejo/cjq008

DO - 10.1093/ejo/cjq008

M3 - Article

VL - 32

SP - 614

EP - 619

JO - European Journal of Orthodontics

JF - European Journal of Orthodontics

SN - 0141-5387

IS - 6

ER -