The effect of various factors on variability of retinal nerve fiber layer thickness measurements using optical coherence tomography.

Dong Ju Youm, Hyunjoong Kim, Seong Hee Shim, Hyo Ju Jang, Joon Mo Kim, K. H. Park, Chul Young Choi, Jung Gon Cho

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

To evaluate the effects of various factors on the variability of retinal nerve fiber layer (RNFL) thickness measurements using the Stratus optical coherence tomography (OCT) in normal and glaucomatous eyes. Four hundred seventy-four subjects (103 normal eyes and 371 glaucomatous eyes) were scanned to determine the RNFL thickness measurements using the Stratus OCT. Measurements were obtained twice during the same day. The standard deviation (SD) was used to compare the variability in RNFL thickness measurements of the normal subjects to that of the glaucomatous patients. Multivariate regression analysis was used to evaluate which covariates were independent predictors of SD in overall mean RNFL thickness. The mean SD of all RNFL thickness measurements was larger in the glaucoma group except in one sector. In the multivariate regression analysis, the average signal strength (SS) and the relative SS change (difference in SS between initial and repeat scans, divided by initial SS) were independent predictors of the SD in the RNFL thickness measurements (partial R(2) = 0.018, 0.013; p = 0.016, 0.040, respectively). Glaucomatous eyes tend to be more variable than normal eyes in RNFL thickness measurement using the Straus OCT. The average SS and the relative SS changes appear to correlate with the variability in RNFL thickness measurement. Therefore, the results of the RNFL analysis should not be interpreted independently of these factors.

Original languageEnglish
Pages (from-to)104-110
Number of pages7
JournalKorean journal of ophthalmology : KJO
Volume26
Issue number2
DOIs
Publication statusPublished - 2012 Jan 1

Fingerprint

Optical Coherence Tomography
Nerve Fibers
Multivariate Analysis
Regression Analysis
Glaucoma

All Science Journal Classification (ASJC) codes

  • Medicine(all)

Cite this

Youm, Dong Ju ; Kim, Hyunjoong ; Shim, Seong Hee ; Jang, Hyo Ju ; Kim, Joon Mo ; Park, K. H. ; Choi, Chul Young ; Cho, Jung Gon. / The effect of various factors on variability of retinal nerve fiber layer thickness measurements using optical coherence tomography. In: Korean journal of ophthalmology : KJO. 2012 ; Vol. 26, No. 2. pp. 104-110.
@article{4a0aaa2bc3714c0492fad989c6c62a24,
title = "The effect of various factors on variability of retinal nerve fiber layer thickness measurements using optical coherence tomography.",
abstract = "To evaluate the effects of various factors on the variability of retinal nerve fiber layer (RNFL) thickness measurements using the Stratus optical coherence tomography (OCT) in normal and glaucomatous eyes. Four hundred seventy-four subjects (103 normal eyes and 371 glaucomatous eyes) were scanned to determine the RNFL thickness measurements using the Stratus OCT. Measurements were obtained twice during the same day. The standard deviation (SD) was used to compare the variability in RNFL thickness measurements of the normal subjects to that of the glaucomatous patients. Multivariate regression analysis was used to evaluate which covariates were independent predictors of SD in overall mean RNFL thickness. The mean SD of all RNFL thickness measurements was larger in the glaucoma group except in one sector. In the multivariate regression analysis, the average signal strength (SS) and the relative SS change (difference in SS between initial and repeat scans, divided by initial SS) were independent predictors of the SD in the RNFL thickness measurements (partial R(2) = 0.018, 0.013; p = 0.016, 0.040, respectively). Glaucomatous eyes tend to be more variable than normal eyes in RNFL thickness measurement using the Straus OCT. The average SS and the relative SS changes appear to correlate with the variability in RNFL thickness measurement. Therefore, the results of the RNFL analysis should not be interpreted independently of these factors.",
author = "Youm, {Dong Ju} and Hyunjoong Kim and Shim, {Seong Hee} and Jang, {Hyo Ju} and Kim, {Joon Mo} and Park, {K. H.} and Choi, {Chul Young} and Cho, {Jung Gon}",
year = "2012",
month = "1",
day = "1",
doi = "10.3341/kjo.2012.26.2.104",
language = "English",
volume = "26",
pages = "104--110",
journal = "Korean journal of ophthalmology : KJO",
issn = "1011-8942",
publisher = "Seoul Kjo",
number = "2",

}

The effect of various factors on variability of retinal nerve fiber layer thickness measurements using optical coherence tomography. / Youm, Dong Ju; Kim, Hyunjoong; Shim, Seong Hee; Jang, Hyo Ju; Kim, Joon Mo; Park, K. H.; Choi, Chul Young; Cho, Jung Gon.

In: Korean journal of ophthalmology : KJO, Vol. 26, No. 2, 01.01.2012, p. 104-110.

Research output: Contribution to journalArticle

TY - JOUR

T1 - The effect of various factors on variability of retinal nerve fiber layer thickness measurements using optical coherence tomography.

AU - Youm, Dong Ju

AU - Kim, Hyunjoong

AU - Shim, Seong Hee

AU - Jang, Hyo Ju

AU - Kim, Joon Mo

AU - Park, K. H.

AU - Choi, Chul Young

AU - Cho, Jung Gon

PY - 2012/1/1

Y1 - 2012/1/1

N2 - To evaluate the effects of various factors on the variability of retinal nerve fiber layer (RNFL) thickness measurements using the Stratus optical coherence tomography (OCT) in normal and glaucomatous eyes. Four hundred seventy-four subjects (103 normal eyes and 371 glaucomatous eyes) were scanned to determine the RNFL thickness measurements using the Stratus OCT. Measurements were obtained twice during the same day. The standard deviation (SD) was used to compare the variability in RNFL thickness measurements of the normal subjects to that of the glaucomatous patients. Multivariate regression analysis was used to evaluate which covariates were independent predictors of SD in overall mean RNFL thickness. The mean SD of all RNFL thickness measurements was larger in the glaucoma group except in one sector. In the multivariate regression analysis, the average signal strength (SS) and the relative SS change (difference in SS between initial and repeat scans, divided by initial SS) were independent predictors of the SD in the RNFL thickness measurements (partial R(2) = 0.018, 0.013; p = 0.016, 0.040, respectively). Glaucomatous eyes tend to be more variable than normal eyes in RNFL thickness measurement using the Straus OCT. The average SS and the relative SS changes appear to correlate with the variability in RNFL thickness measurement. Therefore, the results of the RNFL analysis should not be interpreted independently of these factors.

AB - To evaluate the effects of various factors on the variability of retinal nerve fiber layer (RNFL) thickness measurements using the Stratus optical coherence tomography (OCT) in normal and glaucomatous eyes. Four hundred seventy-four subjects (103 normal eyes and 371 glaucomatous eyes) were scanned to determine the RNFL thickness measurements using the Stratus OCT. Measurements were obtained twice during the same day. The standard deviation (SD) was used to compare the variability in RNFL thickness measurements of the normal subjects to that of the glaucomatous patients. Multivariate regression analysis was used to evaluate which covariates were independent predictors of SD in overall mean RNFL thickness. The mean SD of all RNFL thickness measurements was larger in the glaucoma group except in one sector. In the multivariate regression analysis, the average signal strength (SS) and the relative SS change (difference in SS between initial and repeat scans, divided by initial SS) were independent predictors of the SD in the RNFL thickness measurements (partial R(2) = 0.018, 0.013; p = 0.016, 0.040, respectively). Glaucomatous eyes tend to be more variable than normal eyes in RNFL thickness measurement using the Straus OCT. The average SS and the relative SS changes appear to correlate with the variability in RNFL thickness measurement. Therefore, the results of the RNFL analysis should not be interpreted independently of these factors.

UR - http://www.scopus.com/inward/record.url?scp=84864876149&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84864876149&partnerID=8YFLogxK

U2 - 10.3341/kjo.2012.26.2.104

DO - 10.3341/kjo.2012.26.2.104

M3 - Article

VL - 26

SP - 104

EP - 110

JO - Korean journal of ophthalmology : KJO

JF - Korean journal of ophthalmology : KJO

SN - 1011-8942

IS - 2

ER -