The initiation of the heart beat

Peng Sheng Chen, Boyoung Joung, Tetsuji Shinohara, Mithilesh Das, Zhenhui Chen, Shien Fong Lin

Research output: Contribution to journalReview article

33 Citations (Scopus)

Abstract

During a normal lifetime, the heart may beat over 2 billion times, but the mechanisms by which the heart beats are initiated remain a subject of intense investigation. Since the discovery of a pacemaker current (If ) in 1978, multiple studies have shown that rhythmic changes in membrane voltage (the "membrane voltage clock") underlie the mechanisms of automaticity. The If is a depolarization current activated during hyperpolarization. Therefore, when the cardiac cells recover, the If is activated and slowly depolarizes the cell membrane, leading to the onset of action potential. Recent studies, however, suggest that increased intracellular Ca (Cai) induced by spontaneous rhythmic sarcoplasmic reticulum Ca release (the "calcium clock") is also jointly responsible for the initiation of the heart beat. Elevated Cai activates another ionic current (the sodium-calcium exchanger current or INCX), leading to spontaneous phase 4 depolarization. Under normal conditions, both clocks are needed to initiate the heart beat. Malfunction of the clocks is associated with sinus node dysfunction in heart failure and atrial fibrillation. More studies are needed to determine how both clocks work together to initiate heart beat under normal and disease conditions.

Original languageEnglish
Pages (from-to)221-225
Number of pages5
JournalCirculation Journal
Volume74
Issue number2
DOIs
Publication statusPublished - 2010 Feb 1

Fingerprint

Sodium-Calcium Exchanger
Sick Sinus Syndrome
Membranes
Sarcoplasmic Reticulum
Atrial Fibrillation
Action Potentials
Heart Failure
Cell Membrane
Calcium

All Science Journal Classification (ASJC) codes

  • Cardiology and Cardiovascular Medicine

Cite this

Chen, P. S., Joung, B., Shinohara, T., Das, M., Chen, Z., & Lin, S. F. (2010). The initiation of the heart beat. Circulation Journal, 74(2), 221-225. https://doi.org/10.1253/circj.CJ-09-0712
Chen, Peng Sheng ; Joung, Boyoung ; Shinohara, Tetsuji ; Das, Mithilesh ; Chen, Zhenhui ; Lin, Shien Fong. / The initiation of the heart beat. In: Circulation Journal. 2010 ; Vol. 74, No. 2. pp. 221-225.
@article{1154aa95082e4109ac39fc67f64f0c8f,
title = "The initiation of the heart beat",
abstract = "During a normal lifetime, the heart may beat over 2 billion times, but the mechanisms by which the heart beats are initiated remain a subject of intense investigation. Since the discovery of a pacemaker current (If ) in 1978, multiple studies have shown that rhythmic changes in membrane voltage (the {"}membrane voltage clock{"}) underlie the mechanisms of automaticity. The If is a depolarization current activated during hyperpolarization. Therefore, when the cardiac cells recover, the If is activated and slowly depolarizes the cell membrane, leading to the onset of action potential. Recent studies, however, suggest that increased intracellular Ca (Cai) induced by spontaneous rhythmic sarcoplasmic reticulum Ca release (the {"}calcium clock{"}) is also jointly responsible for the initiation of the heart beat. Elevated Cai activates another ionic current (the sodium-calcium exchanger current or INCX), leading to spontaneous phase 4 depolarization. Under normal conditions, both clocks are needed to initiate the heart beat. Malfunction of the clocks is associated with sinus node dysfunction in heart failure and atrial fibrillation. More studies are needed to determine how both clocks work together to initiate heart beat under normal and disease conditions.",
author = "Chen, {Peng Sheng} and Boyoung Joung and Tetsuji Shinohara and Mithilesh Das and Zhenhui Chen and Lin, {Shien Fong}",
year = "2010",
month = "2",
day = "1",
doi = "10.1253/circj.CJ-09-0712",
language = "English",
volume = "74",
pages = "221--225",
journal = "Circulation Journal",
issn = "1346-9843",
publisher = "Japanese Circulation Society",
number = "2",

}

Chen, PS, Joung, B, Shinohara, T, Das, M, Chen, Z & Lin, SF 2010, 'The initiation of the heart beat', Circulation Journal, vol. 74, no. 2, pp. 221-225. https://doi.org/10.1253/circj.CJ-09-0712

The initiation of the heart beat. / Chen, Peng Sheng; Joung, Boyoung; Shinohara, Tetsuji; Das, Mithilesh; Chen, Zhenhui; Lin, Shien Fong.

In: Circulation Journal, Vol. 74, No. 2, 01.02.2010, p. 221-225.

Research output: Contribution to journalReview article

TY - JOUR

T1 - The initiation of the heart beat

AU - Chen, Peng Sheng

AU - Joung, Boyoung

AU - Shinohara, Tetsuji

AU - Das, Mithilesh

AU - Chen, Zhenhui

AU - Lin, Shien Fong

PY - 2010/2/1

Y1 - 2010/2/1

N2 - During a normal lifetime, the heart may beat over 2 billion times, but the mechanisms by which the heart beats are initiated remain a subject of intense investigation. Since the discovery of a pacemaker current (If ) in 1978, multiple studies have shown that rhythmic changes in membrane voltage (the "membrane voltage clock") underlie the mechanisms of automaticity. The If is a depolarization current activated during hyperpolarization. Therefore, when the cardiac cells recover, the If is activated and slowly depolarizes the cell membrane, leading to the onset of action potential. Recent studies, however, suggest that increased intracellular Ca (Cai) induced by spontaneous rhythmic sarcoplasmic reticulum Ca release (the "calcium clock") is also jointly responsible for the initiation of the heart beat. Elevated Cai activates another ionic current (the sodium-calcium exchanger current or INCX), leading to spontaneous phase 4 depolarization. Under normal conditions, both clocks are needed to initiate the heart beat. Malfunction of the clocks is associated with sinus node dysfunction in heart failure and atrial fibrillation. More studies are needed to determine how both clocks work together to initiate heart beat under normal and disease conditions.

AB - During a normal lifetime, the heart may beat over 2 billion times, but the mechanisms by which the heart beats are initiated remain a subject of intense investigation. Since the discovery of a pacemaker current (If ) in 1978, multiple studies have shown that rhythmic changes in membrane voltage (the "membrane voltage clock") underlie the mechanisms of automaticity. The If is a depolarization current activated during hyperpolarization. Therefore, when the cardiac cells recover, the If is activated and slowly depolarizes the cell membrane, leading to the onset of action potential. Recent studies, however, suggest that increased intracellular Ca (Cai) induced by spontaneous rhythmic sarcoplasmic reticulum Ca release (the "calcium clock") is also jointly responsible for the initiation of the heart beat. Elevated Cai activates another ionic current (the sodium-calcium exchanger current or INCX), leading to spontaneous phase 4 depolarization. Under normal conditions, both clocks are needed to initiate the heart beat. Malfunction of the clocks is associated with sinus node dysfunction in heart failure and atrial fibrillation. More studies are needed to determine how both clocks work together to initiate heart beat under normal and disease conditions.

UR - http://www.scopus.com/inward/record.url?scp=75749139359&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=75749139359&partnerID=8YFLogxK

U2 - 10.1253/circj.CJ-09-0712

DO - 10.1253/circj.CJ-09-0712

M3 - Review article

C2 - 20019407

AN - SCOPUS:75749139359

VL - 74

SP - 221

EP - 225

JO - Circulation Journal

JF - Circulation Journal

SN - 1346-9843

IS - 2

ER -

Chen PS, Joung B, Shinohara T, Das M, Chen Z, Lin SF. The initiation of the heart beat. Circulation Journal. 2010 Feb 1;74(2):221-225. https://doi.org/10.1253/circj.CJ-09-0712