The measurement of compound neural action potential in sciatic nerve using microelectrode array

Chungkeun Lee, Yongho Kim, Hangsik Shin, Yong-Jun Kim, Myoungho Lee

Research output: Chapter in Book/Report/Conference proceedingConference contribution

2 Citations (Scopus)

Abstract

As a method of observing regeneration of damaged nerves, research is being conducted on analyzing the electric signals of nerve fibers that are damaged and regenerating by implanting a microelectrode array between those nerves. Microelectrode arrays possess high impedance and a unique phase characteristic according to their structural features, thus it requires a phase linearity test and an impedance test to prevent neural signal distortion. Therefore, this paper analyzes the features of microelectrode array and designs a bioamplifier. We also measured signals from sciatic nerves in rats with microelectrode array.

Original languageEnglish
Title of host publication28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
Pages3002-3004
Number of pages3
DOIs
Publication statusPublished - 2006 Dec 1
Event28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06 - New York, NY, United States
Duration: 2006 Aug 302006 Sep 3

Publication series

NameAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
ISSN (Print)0589-1019

Other

Other28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
CountryUnited States
CityNew York, NY
Period06/8/3006/9/3

Fingerprint

Microelectrodes
Sciatic Nerve
Action Potentials
Electric Impedance
Signal distortion
Nerve Regeneration
Nerve Fibers
Rats
Fibers
Research

All Science Journal Classification (ASJC) codes

  • Signal Processing
  • Biomedical Engineering
  • Computer Vision and Pattern Recognition
  • Health Informatics

Cite this

Lee, C., Kim, Y., Shin, H., Kim, Y-J., & Lee, M. (2006). The measurement of compound neural action potential in sciatic nerve using microelectrode array. In 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06 (pp. 3002-3004). [4030420] (Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings). https://doi.org/10.1109/IEMBS.2006.260636
Lee, Chungkeun ; Kim, Yongho ; Shin, Hangsik ; Kim, Yong-Jun ; Lee, Myoungho. / The measurement of compound neural action potential in sciatic nerve using microelectrode array. 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06. 2006. pp. 3002-3004 (Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings).
@inproceedings{e6499963bbee49308402949665734327,
title = "The measurement of compound neural action potential in sciatic nerve using microelectrode array",
abstract = "As a method of observing regeneration of damaged nerves, research is being conducted on analyzing the electric signals of nerve fibers that are damaged and regenerating by implanting a microelectrode array between those nerves. Microelectrode arrays possess high impedance and a unique phase characteristic according to their structural features, thus it requires a phase linearity test and an impedance test to prevent neural signal distortion. Therefore, this paper analyzes the features of microelectrode array and designs a bioamplifier. We also measured signals from sciatic nerves in rats with microelectrode array.",
author = "Chungkeun Lee and Yongho Kim and Hangsik Shin and Yong-Jun Kim and Myoungho Lee",
year = "2006",
month = "12",
day = "1",
doi = "10.1109/IEMBS.2006.260636",
language = "English",
isbn = "1424400325",
series = "Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings",
pages = "3002--3004",
booktitle = "28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06",

}

Lee, C, Kim, Y, Shin, H, Kim, Y-J & Lee, M 2006, The measurement of compound neural action potential in sciatic nerve using microelectrode array. in 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06., 4030420, Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, pp. 3002-3004, 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06, New York, NY, United States, 06/8/30. https://doi.org/10.1109/IEMBS.2006.260636

The measurement of compound neural action potential in sciatic nerve using microelectrode array. / Lee, Chungkeun; Kim, Yongho; Shin, Hangsik; Kim, Yong-Jun; Lee, Myoungho.

28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06. 2006. p. 3002-3004 4030420 (Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - The measurement of compound neural action potential in sciatic nerve using microelectrode array

AU - Lee, Chungkeun

AU - Kim, Yongho

AU - Shin, Hangsik

AU - Kim, Yong-Jun

AU - Lee, Myoungho

PY - 2006/12/1

Y1 - 2006/12/1

N2 - As a method of observing regeneration of damaged nerves, research is being conducted on analyzing the electric signals of nerve fibers that are damaged and regenerating by implanting a microelectrode array between those nerves. Microelectrode arrays possess high impedance and a unique phase characteristic according to their structural features, thus it requires a phase linearity test and an impedance test to prevent neural signal distortion. Therefore, this paper analyzes the features of microelectrode array and designs a bioamplifier. We also measured signals from sciatic nerves in rats with microelectrode array.

AB - As a method of observing regeneration of damaged nerves, research is being conducted on analyzing the electric signals of nerve fibers that are damaged and regenerating by implanting a microelectrode array between those nerves. Microelectrode arrays possess high impedance and a unique phase characteristic according to their structural features, thus it requires a phase linearity test and an impedance test to prevent neural signal distortion. Therefore, this paper analyzes the features of microelectrode array and designs a bioamplifier. We also measured signals from sciatic nerves in rats with microelectrode array.

UR - http://www.scopus.com/inward/record.url?scp=34047164655&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34047164655&partnerID=8YFLogxK

U2 - 10.1109/IEMBS.2006.260636

DO - 10.1109/IEMBS.2006.260636

M3 - Conference contribution

C2 - 17947003

AN - SCOPUS:34047164655

SN - 1424400325

SN - 9781424400324

T3 - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

SP - 3002

EP - 3004

BT - 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06

ER -

Lee C, Kim Y, Shin H, Kim Y-J, Lee M. The measurement of compound neural action potential in sciatic nerve using microelectrode array. In 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06. 2006. p. 3002-3004. 4030420. (Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings). https://doi.org/10.1109/IEMBS.2006.260636