TY - JOUR
T1 - Two-year clinical outcomes of zotarolimus- and everolimus-eluting durable-polymer-coated stents versus biolimus-eluting biodegradable-polymer-coated stent in patients with acute myocardial infarction with dyslipidemia after percutaneous coronary intervention
T2 - data from the KAMIR
AU - Kim, Yong Hoon
AU - Her, Ae Young
AU - Jeong, Myung Ho
AU - Kim, Byeong Keuk
AU - Hong, Sung Jin
AU - Shin, Dong Ho
AU - Kim, Jung Sun
AU - Ko, Young Guk
AU - Choi, Donghoon
AU - Hong, Myeong Ki
AU - Jang, Yangsoo
N1 - Publisher Copyright:
© 2018, Springer Japan KK, part of Springer Nature.
PY - 2019/2/15
Y1 - 2019/2/15
N2 - There are limited data comparing the clinical outcomes among new-generation drug-eluting stents (DES) in acute myocardial infarction (AMI) patients with dyslipidemia after percutaneous coronary intervention (PCI). We thought to investigate 2-year clinical outcomes among durable-polymer (DP)-coated stents [zotarolimus eluting (ZES) and everolimus eluting (EES)] and biodegradable-polymer (BP)-coated biolimus-eluting stent (BES) in dyslipidemic AMI patients after PCI. Finally, a total 2403 enrolled patients were divided into ZES (n = 953), EES (n = 1145) or BES (n = 305) group. The primary endpoint was major adverse cardiac events (MACE) defined as total death (TD), cardiac death (CD), myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR) and non-TVR. The secondary endpoint was the incidence of definite or probable stent thrombosis (ST). The 2-year adjusted hazard ratio (HR) of MACE for ZES vs. EES [HR, 1.066; 95% confidence interval (CI) 0.752–1.511; p = 0.720], ZES vs. BES (HR 0.933; 95% CI 0.565–1.541; p = 0.786), EES vs. BES (HR 1.876; 95% CI 0.535–1.436; p = 0.600) and ZES/EES vs. BES (HR 0.929; 95% CI 0.591–1.462; p = 0.751) was similar. The cumulative incidences of ST were comparable (ZES vs. EES vs. BES = 1.1% vs. 0.9% vs. 1.1%, p = 0.675) and adjusted HR was not different. In addition, the 2-year adjusted HR of TD, CD, MI, TLR, TVR, and non-TVR was similar. The AMI patients with dyslipidemia receiving ZES, EES, or BES after PCI showed comparable safety and efficacy during 2-year follow-up periods. Therefore, DP-DES or BP-DES is equally acceptable in dyslipidemic AMI patients during PCI.
AB - There are limited data comparing the clinical outcomes among new-generation drug-eluting stents (DES) in acute myocardial infarction (AMI) patients with dyslipidemia after percutaneous coronary intervention (PCI). We thought to investigate 2-year clinical outcomes among durable-polymer (DP)-coated stents [zotarolimus eluting (ZES) and everolimus eluting (EES)] and biodegradable-polymer (BP)-coated biolimus-eluting stent (BES) in dyslipidemic AMI patients after PCI. Finally, a total 2403 enrolled patients were divided into ZES (n = 953), EES (n = 1145) or BES (n = 305) group. The primary endpoint was major adverse cardiac events (MACE) defined as total death (TD), cardiac death (CD), myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR) and non-TVR. The secondary endpoint was the incidence of definite or probable stent thrombosis (ST). The 2-year adjusted hazard ratio (HR) of MACE for ZES vs. EES [HR, 1.066; 95% confidence interval (CI) 0.752–1.511; p = 0.720], ZES vs. BES (HR 0.933; 95% CI 0.565–1.541; p = 0.786), EES vs. BES (HR 1.876; 95% CI 0.535–1.436; p = 0.600) and ZES/EES vs. BES (HR 0.929; 95% CI 0.591–1.462; p = 0.751) was similar. The cumulative incidences of ST were comparable (ZES vs. EES vs. BES = 1.1% vs. 0.9% vs. 1.1%, p = 0.675) and adjusted HR was not different. In addition, the 2-year adjusted HR of TD, CD, MI, TLR, TVR, and non-TVR was similar. The AMI patients with dyslipidemia receiving ZES, EES, or BES after PCI showed comparable safety and efficacy during 2-year follow-up periods. Therefore, DP-DES or BP-DES is equally acceptable in dyslipidemic AMI patients during PCI.
UR - http://www.scopus.com/inward/record.url?scp=85052806883&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85052806883&partnerID=8YFLogxK
U2 - 10.1007/s00380-018-1251-0
DO - 10.1007/s00380-018-1251-0
M3 - Article
C2 - 30167772
AN - SCOPUS:85052806883
SN - 0910-8327
VL - 34
SP - 237
EP - 250
JO - Heart and Vessels
JF - Heart and Vessels
IS - 2
ER -