Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: Impedance spectroscopy and time-difference imaging

Tong In Oh, Hwan Koo, Kyung Heon Lee, Sang Min Kim, Jeehyun Lee, Sung Wan Kim, Jin Keun Seo, Eung Je Woo

Research output: Contribution to journalArticle

67 Citations (Scopus)

Abstract

Validation and interpretation of reconstructed images using a multi-frequency electrical impedance tomography (mfEIT) requires a conductivity phantom including imaging objects with known complex conductivity (σ + iωε) spectra. We describe imaging experiments using the recently developed mfEIT system called the KHU Mark1 with the frequency range of 10 Hz to 500 kHz. Using a bio-impedance spectroscopy (BIS) system, we first measured complex conductivity spectra of different imaging objects including saline, agar, polyacrylamide, TX151, animal hide gelatin, banana and cucumber. Based on an analysis of how conductivity and permittivity affect measured complex boundary voltages, we suggested a new complex version of a multi-frequency time-difference image reconstruction algorithm. Imaging experiments were conducted to produce time-difference images of the objects at multiple frequencies using the proposed algorithm. Images of a conductor (stainless steel) and an insulator (acrylic plastic) were used to set a common scale bar to display all images. Comparing reconstructed time-difference images at multiple frequencies with measured complex conductivity spectra, we found that they showed an overall similarity in terms of changes in complex conductivity values with respect to frequency. However, primarily due to the limitation of the difference imaging algorithm, we suggest that multi-frequency time-difference images must be interpreted in terms of relative contrast changes with respect to frequency. We propose further imaging studies using biological tissues of known complex conductivity spectra and using human subjects to find clinical applications of the mfEIT system.

Original languageEnglish
Pages (from-to)295-307
Number of pages13
JournalPhysiological measurement
Volume29
Issue number3
DOIs
Publication statusPublished - 2008 Mar 1

Fingerprint

Dielectric Spectroscopy
Acoustic impedance
Electric Impedance
Tomography
Spectroscopy
Imaging techniques
Imaging Phantoms
Cucumis sativus
Musa
Computer-Assisted Image Processing
Stainless Steel
Gelatin
Plastics
Agar
Polyacrylates
Image reconstruction
Acrylics
Animals
Permittivity
Stainless steel

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Physiology
  • Biomedical Engineering
  • Physiology (medical)

Cite this

Oh, Tong In ; Koo, Hwan ; Lee, Kyung Heon ; Kim, Sang Min ; Lee, Jeehyun ; Kim, Sung Wan ; Seo, Jin Keun ; Woo, Eung Je. / Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1 : Impedance spectroscopy and time-difference imaging. In: Physiological measurement. 2008 ; Vol. 29, No. 3. pp. 295-307.
@article{f96fb1277dbe4f938da191970d1d8bba,
title = "Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: Impedance spectroscopy and time-difference imaging",
abstract = "Validation and interpretation of reconstructed images using a multi-frequency electrical impedance tomography (mfEIT) requires a conductivity phantom including imaging objects with known complex conductivity (σ + iωε) spectra. We describe imaging experiments using the recently developed mfEIT system called the KHU Mark1 with the frequency range of 10 Hz to 500 kHz. Using a bio-impedance spectroscopy (BIS) system, we first measured complex conductivity spectra of different imaging objects including saline, agar, polyacrylamide, TX151, animal hide gelatin, banana and cucumber. Based on an analysis of how conductivity and permittivity affect measured complex boundary voltages, we suggested a new complex version of a multi-frequency time-difference image reconstruction algorithm. Imaging experiments were conducted to produce time-difference images of the objects at multiple frequencies using the proposed algorithm. Images of a conductor (stainless steel) and an insulator (acrylic plastic) were used to set a common scale bar to display all images. Comparing reconstructed time-difference images at multiple frequencies with measured complex conductivity spectra, we found that they showed an overall similarity in terms of changes in complex conductivity values with respect to frequency. However, primarily due to the limitation of the difference imaging algorithm, we suggest that multi-frequency time-difference images must be interpreted in terms of relative contrast changes with respect to frequency. We propose further imaging studies using biological tissues of known complex conductivity spectra and using human subjects to find clinical applications of the mfEIT system.",
author = "Oh, {Tong In} and Hwan Koo and Lee, {Kyung Heon} and Kim, {Sang Min} and Jeehyun Lee and Kim, {Sung Wan} and Seo, {Jin Keun} and Woo, {Eung Je}",
year = "2008",
month = "3",
day = "1",
doi = "10.1088/0967-3334/29/3/002",
language = "English",
volume = "29",
pages = "295--307",
journal = "Physiological Measurement",
issn = "0967-3334",
publisher = "IOP Publishing Ltd.",
number = "3",

}

Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1 : Impedance spectroscopy and time-difference imaging. / Oh, Tong In; Koo, Hwan; Lee, Kyung Heon; Kim, Sang Min; Lee, Jeehyun; Kim, Sung Wan; Seo, Jin Keun; Woo, Eung Je.

In: Physiological measurement, Vol. 29, No. 3, 01.03.2008, p. 295-307.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1

T2 - Impedance spectroscopy and time-difference imaging

AU - Oh, Tong In

AU - Koo, Hwan

AU - Lee, Kyung Heon

AU - Kim, Sang Min

AU - Lee, Jeehyun

AU - Kim, Sung Wan

AU - Seo, Jin Keun

AU - Woo, Eung Je

PY - 2008/3/1

Y1 - 2008/3/1

N2 - Validation and interpretation of reconstructed images using a multi-frequency electrical impedance tomography (mfEIT) requires a conductivity phantom including imaging objects with known complex conductivity (σ + iωε) spectra. We describe imaging experiments using the recently developed mfEIT system called the KHU Mark1 with the frequency range of 10 Hz to 500 kHz. Using a bio-impedance spectroscopy (BIS) system, we first measured complex conductivity spectra of different imaging objects including saline, agar, polyacrylamide, TX151, animal hide gelatin, banana and cucumber. Based on an analysis of how conductivity and permittivity affect measured complex boundary voltages, we suggested a new complex version of a multi-frequency time-difference image reconstruction algorithm. Imaging experiments were conducted to produce time-difference images of the objects at multiple frequencies using the proposed algorithm. Images of a conductor (stainless steel) and an insulator (acrylic plastic) were used to set a common scale bar to display all images. Comparing reconstructed time-difference images at multiple frequencies with measured complex conductivity spectra, we found that they showed an overall similarity in terms of changes in complex conductivity values with respect to frequency. However, primarily due to the limitation of the difference imaging algorithm, we suggest that multi-frequency time-difference images must be interpreted in terms of relative contrast changes with respect to frequency. We propose further imaging studies using biological tissues of known complex conductivity spectra and using human subjects to find clinical applications of the mfEIT system.

AB - Validation and interpretation of reconstructed images using a multi-frequency electrical impedance tomography (mfEIT) requires a conductivity phantom including imaging objects with known complex conductivity (σ + iωε) spectra. We describe imaging experiments using the recently developed mfEIT system called the KHU Mark1 with the frequency range of 10 Hz to 500 kHz. Using a bio-impedance spectroscopy (BIS) system, we first measured complex conductivity spectra of different imaging objects including saline, agar, polyacrylamide, TX151, animal hide gelatin, banana and cucumber. Based on an analysis of how conductivity and permittivity affect measured complex boundary voltages, we suggested a new complex version of a multi-frequency time-difference image reconstruction algorithm. Imaging experiments were conducted to produce time-difference images of the objects at multiple frequencies using the proposed algorithm. Images of a conductor (stainless steel) and an insulator (acrylic plastic) were used to set a common scale bar to display all images. Comparing reconstructed time-difference images at multiple frequencies with measured complex conductivity spectra, we found that they showed an overall similarity in terms of changes in complex conductivity values with respect to frequency. However, primarily due to the limitation of the difference imaging algorithm, we suggest that multi-frequency time-difference images must be interpreted in terms of relative contrast changes with respect to frequency. We propose further imaging studies using biological tissues of known complex conductivity spectra and using human subjects to find clinical applications of the mfEIT system.

UR - http://www.scopus.com/inward/record.url?scp=41049091399&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=41049091399&partnerID=8YFLogxK

U2 - 10.1088/0967-3334/29/3/002

DO - 10.1088/0967-3334/29/3/002

M3 - Article

C2 - 18367806

AN - SCOPUS:41049091399

VL - 29

SP - 295

EP - 307

JO - Physiological Measurement

JF - Physiological Measurement

SN - 0967-3334

IS - 3

ER -