Wearable tubing assistive walking device immediately enhances gait parameters in subjects with stroke: A randomized controlled study

Seung Mi Lee, Heon Seock Cynn, Chung Hwi Yi, Tae Lim Yoon, Ji Hyun Lee

Research output: Contribution to journalArticle

Abstract

BACKGROUND: Stroke patients develop compensatory movements due to limitations of ankle dorsiflexion and knee flexion. To solve the limitations, there are many adjustable walking assistive devices such as robotic devices, ankle-foot orthoses, and functional electric stimulation in rehabilitation session. However, these assistive devices have some disadvantages, including expense and discomforts. Therefore, the development of a new assistive device for stroke patients is needed to assist ankle dorsiflexion and knee flexion. OBJECTIVE: This study investigated the effects of a wearable tubing assistive walking device (WTAWD) on gait parameters (gait speed, cadence, and step length and stride length on affected and less affected sides) in patients with stroke. METHODS: Gait parameters were measured using the GAITRite system. One-way repeated measures analysis of variance was used to determine gait differences under three conditions (WTAWD, barefoot, and conventional elastic band orthosis). RESULTS: Gait speed, cadence, and step length and stride length on both affected and less affected sides were significantly greater with WTAWD, compared to barefoot and conventional elastic band orthosis conditions. CONCLUSION: WTAWD could be effective for patients with stroke.

Original languageEnglish
Pages (from-to)99-107
Number of pages9
JournalNeuroRehabilitation
Volume40
Issue number1
DOIs
Publication statusPublished - 2017 Jan 1

Fingerprint

Self-Help Devices
Gait
Walking
Stroke
Ankle
Orthotic Devices
Knee
Foot Orthoses
Robotics
Electric Stimulation
Analysis of Variance
Rehabilitation
Equipment and Supplies

All Science Journal Classification (ASJC) codes

  • Physical Therapy, Sports Therapy and Rehabilitation
  • Rehabilitation
  • Clinical Neurology

Cite this

@article{35d23af2d59a447897e3f7da10e0b7d4,
title = "Wearable tubing assistive walking device immediately enhances gait parameters in subjects with stroke: A randomized controlled study",
abstract = "BACKGROUND: Stroke patients develop compensatory movements due to limitations of ankle dorsiflexion and knee flexion. To solve the limitations, there are many adjustable walking assistive devices such as robotic devices, ankle-foot orthoses, and functional electric stimulation in rehabilitation session. However, these assistive devices have some disadvantages, including expense and discomforts. Therefore, the development of a new assistive device for stroke patients is needed to assist ankle dorsiflexion and knee flexion. OBJECTIVE: This study investigated the effects of a wearable tubing assistive walking device (WTAWD) on gait parameters (gait speed, cadence, and step length and stride length on affected and less affected sides) in patients with stroke. METHODS: Gait parameters were measured using the GAITRite system. One-way repeated measures analysis of variance was used to determine gait differences under three conditions (WTAWD, barefoot, and conventional elastic band orthosis). RESULTS: Gait speed, cadence, and step length and stride length on both affected and less affected sides were significantly greater with WTAWD, compared to barefoot and conventional elastic band orthosis conditions. CONCLUSION: WTAWD could be effective for patients with stroke.",
author = "Lee, {Seung Mi} and Cynn, {Heon Seock} and Yi, {Chung Hwi} and Yoon, {Tae Lim} and Lee, {Ji Hyun}",
year = "2017",
month = "1",
day = "1",
doi = "10.3233/NRE-161394",
language = "English",
volume = "40",
pages = "99--107",
journal = "NeuroRehabilitation",
issn = "1053-8135",
publisher = "IOS Press",
number = "1",

}

Wearable tubing assistive walking device immediately enhances gait parameters in subjects with stroke : A randomized controlled study. / Lee, Seung Mi; Cynn, Heon Seock; Yi, Chung Hwi; Yoon, Tae Lim; Lee, Ji Hyun.

In: NeuroRehabilitation, Vol. 40, No. 1, 01.01.2017, p. 99-107.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Wearable tubing assistive walking device immediately enhances gait parameters in subjects with stroke

T2 - A randomized controlled study

AU - Lee, Seung Mi

AU - Cynn, Heon Seock

AU - Yi, Chung Hwi

AU - Yoon, Tae Lim

AU - Lee, Ji Hyun

PY - 2017/1/1

Y1 - 2017/1/1

N2 - BACKGROUND: Stroke patients develop compensatory movements due to limitations of ankle dorsiflexion and knee flexion. To solve the limitations, there are many adjustable walking assistive devices such as robotic devices, ankle-foot orthoses, and functional electric stimulation in rehabilitation session. However, these assistive devices have some disadvantages, including expense and discomforts. Therefore, the development of a new assistive device for stroke patients is needed to assist ankle dorsiflexion and knee flexion. OBJECTIVE: This study investigated the effects of a wearable tubing assistive walking device (WTAWD) on gait parameters (gait speed, cadence, and step length and stride length on affected and less affected sides) in patients with stroke. METHODS: Gait parameters were measured using the GAITRite system. One-way repeated measures analysis of variance was used to determine gait differences under three conditions (WTAWD, barefoot, and conventional elastic band orthosis). RESULTS: Gait speed, cadence, and step length and stride length on both affected and less affected sides were significantly greater with WTAWD, compared to barefoot and conventional elastic band orthosis conditions. CONCLUSION: WTAWD could be effective for patients with stroke.

AB - BACKGROUND: Stroke patients develop compensatory movements due to limitations of ankle dorsiflexion and knee flexion. To solve the limitations, there are many adjustable walking assistive devices such as robotic devices, ankle-foot orthoses, and functional electric stimulation in rehabilitation session. However, these assistive devices have some disadvantages, including expense and discomforts. Therefore, the development of a new assistive device for stroke patients is needed to assist ankle dorsiflexion and knee flexion. OBJECTIVE: This study investigated the effects of a wearable tubing assistive walking device (WTAWD) on gait parameters (gait speed, cadence, and step length and stride length on affected and less affected sides) in patients with stroke. METHODS: Gait parameters were measured using the GAITRite system. One-way repeated measures analysis of variance was used to determine gait differences under three conditions (WTAWD, barefoot, and conventional elastic band orthosis). RESULTS: Gait speed, cadence, and step length and stride length on both affected and less affected sides were significantly greater with WTAWD, compared to barefoot and conventional elastic band orthosis conditions. CONCLUSION: WTAWD could be effective for patients with stroke.

UR - http://www.scopus.com/inward/record.url?scp=85015075055&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85015075055&partnerID=8YFLogxK

U2 - 10.3233/NRE-161394

DO - 10.3233/NRE-161394

M3 - Article

C2 - 27935557

AN - SCOPUS:85015075055

VL - 40

SP - 99

EP - 107

JO - NeuroRehabilitation

JF - NeuroRehabilitation

SN - 1053-8135

IS - 1

ER -